ADuM1440/ADuM1441/ADuM1442/ADuM1445/ADuM1446/ADuM1447  Data Sheet 
Rev. E | Page 8 of 25 
ELECTRICAL CHARACTERISTICS—V
DD1
 = 2.5 V, V
DD2
 = 3.3 V OPERATION 
All typical specifications are at T
A
 = 25°C, V
DD1
 = 2.5, and V
DD2
 = 3.3 V.
Minimum/maximum specifications apply over the entire 
recommended operating range of 2.25 V ≤ V
DD1
 ≤ 2.75 V, 3.0 V ≤ V
DD2
 ≤ 3.6 V, and −40°C ≤ T
A
 ≤ +125°C, unless otherwise noted. 
Switching specifications are tested with C
L
 = 15 pF, and CMOS signal levels, unless otherwise noted. 
For dc specifications and ac specifications, see Table 6 for Side 1 and see Table 3 for Side 2. 
Table 9.  
Parameter  Symbol  Min  Typ  Max  Unit  Test Conditions/Comments 
SWITCHING SPECIFICATIONS             
Data Rate        2  Mbps  Within PWD limit 
Propagation Delay             
Side 1 to Side 2 
t
PHL, 
t
PLH
120 
180 
ns 
50% input to 50% output 
Side 2 to Side 1  t
PHL, 
t
PLH
    84  180  ns  50% input to 50% output 
Change vs. Temperature      200    ps/°C   
Pulse-Width Distortion  PWD      12  ns  |t
PLH
 − t
PHL
|  
Pulse Width  PW  500      ns  Within PWD limit 
Propagation Delay Skew
1 
t
PSK
10 
ns 
Channel Matching              
Codirectional  t
PSKCD
      10  ns   
Opposing Direction  t
PSKOD
      60  ns   
1
 t
PSK
 is the magnitude of the worst-case difference in t
PHL
 or t
PLH
 that is measured between units at the same operating temperature, supply voltages, and output load within the 
recommended operating conditions. 
Table 10.  
Parameter  Symbol  Min  Typ  Max  Unit  Test Conditions/Comments 
SUPPLY CURRENT            2 Mbps, no load 
ADuM1440/ADuM1445  I
DD1
    623  1000  µA  EN
X
 = 0 V, V
IH
 = V
DD
, V
IL
 = 0 V 
  I
DD2
    492  750  µA  EN
X
 = 0 V, V
IH
 = V
DD
, V
IL
 = 0 V 
ADuM1441/ADuM1446  I
DD1
    552  750  µA  EN
X
 = 0 V, V
IH
 = V
DD
, V
IL
 = 0 V 
  I
DD2
    552  900  µA  EN
X
 = 0 V, V
IH
 = V
DD
, V
IL
 = 0 V 
ADuM1442/ADuM1447  I
DD1
    480  750  µA  EN
X
 = 0 V, V
IH
 = V
DD
, V
IL
 = 0 V 
  I
DD2
    612  900  µA  EN
X
 = 0 V, V
IH
 = V
DD
, V
IL
 = 0 V 