Data Sheet ADuM2400/ADuM2401/ADuM2402
Rev. F | Page 11 of 24
DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS
These isolators are suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by
means of protective circuits.
Note that the * marking on packages denotes DIN V VDE V 0884-10 approval for 846 V peak working voltage.
Table 7.
Description Conditions Symbol Characteristic Unit
Installation Classification per DIN VDE 0110
For Rated Mains Voltage 300 V rms I to IV
For Rated Mains Voltage 450 V rms I to II
For Rated Mains Voltage ≤ 600 V rms I to II
Climatic Classification 40/105/21
Pollution Degree (DIN VDE 0110, Table 1) 2
Maximum Working Insulation Voltage V
IORM
846 V peak
Input-to-Output Test Voltage, Method b1 V
IORM
× 1.875 = V
PR
, 100% production test, t
m
= 1 sec,
partial discharge < 5 pC
V
PR
1590 V peak
Input-to-Output Test Voltage, Method a V
PR
After Environmental Tests Subgroup 1 V
IORM
× 1.6 = V
PR
, t
m
= 60 sec, partial discharge < 5 pC 1375 V peak
After Input and/or Safety Test Subgroup 2
and Subgroup 3
V
IORM
× 1.2 = V
PR
, t
m
= 60 sec, partial discharge < 5 pC 1018 V peak
Highest Allowable Overvoltage Transient overvoltage, t
TR
= 10 seconds V
TR
6000 V peak
Safety-Limiting Values Maximum value allowed in the event of a failure;
see Figure 4
Case Temperature T
S
150 °C
Side 1 Current I
S1
265 mA
Side 2 Current I
S2
335 mA
Insulation Resistance at T
S
V
IO
= 500 V R
S
>10
9
Ω
CASE TEMPERATURE (°C)
SAFETY-LIMITING CURRENT (mA)
0
0
350
300
250
200
150
100
50
50 100 150
200
SIDE #1
SIDE #2
05007-004
Figure 4. Thermal Derating Curve, Dependence of Safety-Limiting
Values with Case Temperature per DIN V VDE V 0884-10
RECOMMENDED OPERATING CONDITIONS
Table 8.
Parameter Rating
Operating Temperature (T
A
) −40°C to +105°C
Supply Voltages
1
(V
DD1
, V
DD2
)
2.7 V to 5.5 V
Input Signal Rise and Fall Times 1.0 ms
1
All voltages are relative to their respective ground.