Datasheet

ADuM2400/ADuM2401/ADuM2402 Data Sheet
Rev. F | Page 10 of 24
PACKAGE CHARACTERISTICS
Table 4.
Parameter Symbol Min Typ Max Unit Test Conditions
Resistance (Input to Output)
1
R
I-O
10
12
Ω
Capacitance (Input to Output)
1
C
I-O
2.2 pF f = 1 MHz
Input Capacitance
2
C
I
4.0 pF
IC Junction-to-Case Thermal Resistance, Side 1 θ
JCI
33 °C/W Thermocouple located at center
of package underside
IC Junction-to-Case Thermal Resistance, Side 2 θ
JCO
28 °C/W
1
Device considered a 2-terminal device: Pin 1, Pin 2, Pin 3, Pin 4, Pin 5, Pin 6, Pin 7, and Pin 8 shorted together and Pin 9, Pin 10, Pin 11, Pin 12, Pin 13, Pin 14, Pin 15, and
Pin 16 shorted together.
2
Input capacitance is from any input data pin to ground.
REGULATORY INFORMATION
The ADuM2400/ADuM2401/ADuM2402 are approved by the organizations listed in Table 5. Refer to Table 10 and the Insulation Lifetime
section for details regarding recommended maximum working voltages for specific cross-isolation waveforms and insulation levels.
Table 5.
UL CSA CQC VDE
Recognized Under UL 1577
Component Recognition
Program
1
Approved under CSA Component Acceptance
Notice 5A
Approved under CQC11-471543-2012
Certified according to
DIN V VDE V 0884-10
(VDE V 0884-10): 2006-12
2
Single Protection 5000 V rms
Isolation Voltage
Basic insulation per CSA 60950-1-07 and
IEC 60950-1, 600 V rms (848 V peak) maximum
working voltage
Basic insulation per GB4943.1-2011,
600 V rms(848 V peak) maximum
working voltage, tropical climate,
altitude 5000 m
Reinforced insulation,
846 V peak
RW-16 package: reinforced insulation per
CSA 60950-1-07 and IEC 60950-1, 380 V rms
(537 V peak) maximum working voltage;
reinforced insulation per IEC 60601-1
125 V rms (176 V peak) maximum working
voltage
RW-16 package: reinforced insulation
per GB4943.1-2011, 380 V rms
(537 V peak) maximum working
voltage, tropical climate, altitude
5000 m
RI-16 package: reinforced insulation per
CSA 60950-1-07 and IEC 60950-1, 400 V rms
(565 V peak) maximum working voltage;
reinforced insulation per IEC 60601-1 250 V rms
(353 V peak) maximum working voltage
RI-16 package: reinforced insulation
per 400 V rms (565 V peak) maximum
working voltage, tropical climate,
altitude 5000 m
File E214100
File 205078
File: CQC14001108690
File 2471900-4880-0001
1
In accordance with UL 1577, each ADuM2400/ADuM2401/ADuM2402 is proof tested by applying an insulation test voltage ≥ 6000 V rms for 1 sec (current leakage
detection limit = 10 µA).
2
In accordance with DIN V VDE V 0884-10, each ADuM2400/ADuM2401/ADuM2402 is proof tested by applying an insulation test voltage ≥1590 V peak for 1 sec (partial
discharge detection limit = 5 pC). The * marking branded on the component designates DIN V VDE V 0884-10
approval.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
Parameter Symbol Value Unit Conditions
Rated Dielectric Insulation Voltage 5000 V rms 1-minute duration
Minimum External Air Gap L(I01) 8.0 min mm Distance measured from input terminals to output terminals, shortest
distance through air along the PCB mounting plane, as an aid to PC
board layout
Minimum External Tracking (Creepage) RW-16
Package
L(I02) 7.7 min mm Measured from input terminals to output terminals, shortest distance
path along body
Minimum External Tracking (Creepage) RI-16
Package
L(I02) 8.3 min mm Measured from input terminals to output terminals, shortest distance
path along body
Minimum Internal Gap (Internal Clearance)
0.017 min
mm
Insulation distance through insulation
Tracking Resistance (Comparative Tracking
Index)
CTI >400 V DIN IEC 112/VDE 0303 Part 1
Isolation Group II Material Group (DIN VDE 0110, 1/89, Table 1)