Datasheet
Preliminary Technical Data EVAL-ADM106x
renamed to 5V_IN. All references to the VP1 pin in the software
are then updated with the new name. However, pressing the ‘Reset
Pin Names To Default Names’ Button will reset all pin names
throughout the program to the names as shown in the data sheet.
The pin name update window is shown in Figure 30 below:-
Figure 31. Pin Names window- default pin names
Figure 32. Pin Names window- altered pin names
Figure 33. ADM1062 Top Level- revised pin names
SUPPLY FAULT DETECTOR INPUTS
The ADM106x features ten supply fault detector inputs (eight
inputs in the case of ADM1068/9). These supply fault
detectors (SFD) inputs are highly programmable circuits which
provide the following features:-
1. Under AND Over-voltage detection or more
specifically under-voltage (UV), over-voltage (OV)
and out of window detection (UV & OV)
2. Programmable UV and OV threshold
3. Adjustable Hysterisis on every threshold
4. Up to 100us glitch filter to provide supply noise
immunity
The inputs can be categorized in two groups- the VX pins and
the VP/VH pins. The VP/VH pins are analog fault detectors
only. The VX pins have a dual (analog and digital) input
function. The software configuration of both types of inputs is
described below.
Figure 34. Inputs window- nothing programmed
SELECTING THE INPUTS
Any one of the ten inputs (eight for ADM1068/9) can be
selected by left clicking in the drop down box shown below.
Once selected, all of the functions altered in the window effect
only the selected input. To configure another input simply
select another one from the drop down box:-
Rev. PrB | Page 21 of 38