User manual
50
It is strongly recommended reseng all of the default values of your Pulse² unit before seng up your shows 
and events. This will help eliminate confusion caused by unneeded sengs from a previous operator. To do 
so, press the  buon and select Control in the menu by rotang the corresponding knob. Then 
press the ENTER buon to enter  the    sub-menu.  Select  Default  Values  by  rotang  the  scroll 
knob, and press the ENTER buon to enter your choice to restart your Pulse² with its factory sengs. This 
operaon should take approximately 30 seconds.
Analog Way engineers have developed a handy, user friendly way of idenfying machine status on the front 
panel, via the use of color codes on the buons of the machine. All new Analog Way machines use the same 
codes, for quick recognion of the status of any device of the range, at any given me.
For the Pulse², buon color codes are as follow:
• Sources on the Program output are indicated in red when acve,
• Sources on the Preview output are indicated in green when acve,
• Buons  in  the  layer  secon  turn  red  or  green,  depending  on  whether  the  selected  layer  is  acve  in 
respecvely the Program or Preview window,
• menu buons are indicated in green,
• Selecng a buon with an available source or funcon will cause that buon to blink green on the preview, 
or red once it is on the Program output,
• TAKE buon reacts as follows: 
- If take funcon is available, the buon will appear in green. 
- When the take funcon is acve, it will light up red.
8.1.4 Reseng default values
#1 = Source is on the Program output
#2 = Freeze enable
Blinking red:
Blinking green: 
#1 = Source is on Preview
#2 = Funcon available for modicaon
#3 = Current output on Matrix mode
Layer/source selected or is currently acve 
on the Program output
Layer/source selected or is not currently 
acve on the Program output
8.2 
Plug your sources using the 4 mul-plug inputs, 2 HDMI Inputs or 2 3G/HD/SD-SDI inputs.
Be sure that all connectors are rmly aached using all available locking screws.
To set up your inputs automacally:
You can also do it manually on each input# using the ENTER and the Knob buon and set up the inputs type 
one by one.
You can also check your actual input conguraon using the cong status: 