INSTALLATION & OPERATION MANUAL VCH10 Voltage Converter An ISO9001 and AS9100 Registered Company Battery Chargers • Inverters • Power Supplies • Voltage Converters 8128 River Way, Delta B.C. V4G 1K5 Canada T. 604.946.9981 F. 604.946.9983 TF. 800.668.3884 (US/CANADA) www.analyticsystems.
Copyright (2005-2016) Analytic Systems Ware (1993) Ltd.
IMPORTANT & SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS — this user guide contains important safety and operating instructions for the battery charger. VOLTAGE CONVERTER PRECAUTIONS 1. Do not expose the voltage converter to rain or snow unless it is a sealed model. 2. Use of an attachment not recommended or sold by the manufacturer may result in a risk of fire, electric shock, or injury to persons. 3.
Introduction The VCH10 Step Down series of Voltage Converters supply up to 10 amps of output current at 12, 24, 36 or 48 volts from any higher voltage between 20 and 80 volts DC for use in automotive, heavy equipment, marine, industrial, rail or alternative energy environments. All surface mount high frequency design offers higher reliability, higher efficiency (more than 92%), more power (up to 544 watts at 48 VDC Out) and minimum size.
Specifications Input Model VCH10-12 VCH10-24 VCH10-32 VCD10-36 VCH10-48 Input Volts VDC 20 - 80 30 - 80 40 - 80 45 - 80 60 - 80 Input Fuse CB61F15A - 15 Amp Surface Mount Output Nominal VDC 12 24 32 36 48 Actual 13.6 27.2 36.3 40.8 54.4 96.8% 97.1% 97.8% Output Amps 10 Amps Dissipation 12 Watts Efficiency 91.9% 95.8% Electrical Input Ripple & Noise < 100 mV Peak to Peak Output Ripple & Noise < 50 mV Peak to Peak Regulation (Line & Load) < +/- 0.
Installation MOUNTING Mount the unit in a DRY location on any convenient surface using #8 screws. POWER CONNECTION The unit is equipped with a terminal strip for easy connection. Markings on the unit indicate the proper wire connections. IN + Input Positive IN - Input Negative BATT - Battery Negative BATT + Battery Positive Operation The unit will operate whenever power is connected. The ON led will be illuminated whenever power is connected to the charger.
Limited Warranty 1. The equipment manufactured by Analytic Systems Ware (1993) Ltd. (the “Warrantor”) is warranted to be free from defects in workmanship and materials under normal use and service. 2. This warranty is in effect for: a. 3 Years from date of purchase by the end user for standard products offered in our catalog. b. 2 Years from date of manufacture for non-standard or OEM products c. 1 Year from date of manufacture for encapsulated products. 3.
An ISO9001 and AS9100 Registered Company Battery Chargers • Inverters • Power Supplies • Voltage Converters 8128 River Way, Delta B.C. V4G 1K5 Canada T. 604.946.9981 F. 604.946.9983 TF. 800.668.3884 (US/CANADA) www.analyticsystems.