INSTALLATION & OPERATION MANUAL VTC120 Series Voltage Converter An ISO9001 and AS9100 Registered Company Battery Chargers • Inverters • Power Supplies • Voltage Converters 8128 River Way, Delta B.C. V4G 1K5 Canada T. 604.946.9981 F. 604.946.9983 TF. 800.668.3884 (US/CANADA) www.analyticsystems.
Copyright (2005-2016) Analytic Systems Ware (1993) Ltd.
IMPORTANT & SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS — This manual contains important safety and operating instructions for the converter. 1. GENERAL 1. WARNING — Unless the label specifically states that the converter may be used for battery charging, it must not be used for that purpose. 2. CAUTION — To reduce risk of injury, charge only lead acid or sealed gel cell type rechargeable batteries. Other types of batteries may burst causing personal injury and damage. (Applies to battery chargers only!) 3.
Introduction The VTC120 Series Voltage Converter is a variable duty cycle switching power supply with a precision linear regulator output except for the VTC120nr-12-24. It can be configured to run from a 12 VDC or 24 VDC battery system to provide output voltages as shown below. Depending on the version, the output is either Common Negative, or Fully Isolated from the input. Three high output versions are also available.
Isolated High Output Model (VTC120) ih-12-12 ih-12-15.6 ih-12-24 ih-24-12 ih-24-24 ih-36-15.6 ih-48-15.6 ih-48-12 Input Volts (DC) 11 – 15 11 – 15 11 – 15 22 - 30 22 - 30 33 – 45 40 – 60 40 – 60 Input Amps (max) 11 14.2 21.8 6.2 10.9 4.8 3.9 3.0 Input Fuse AGC-15 AGC-20 AGC-25 MDA-7 AGC-15 MDA-8 MDA-7 MDA-7 Output Volts (DC) 12.0 15.6 24.0 12.0 24.0 15.6 15.6 12.0 Output Amps 7.5 Continuous / 8.
POWER CONNECTION The ON/OFF switch must be in the OFF position before connecting or disconnecting power to the unit! A terminal strip is provided at one end of the unit for connecting input and output leads. Connect leads as follows: Input Positive to IN + Output Negative to OUT - Input Negative to IN - Output Positive to OUT + Ensure that the total average load connected does not exceed the continuous current rating of the unit.
Limited Warranty 1. The equipment manufactured by Analytic Systems Ware (1993) Ltd. (the “Warrantor”) is warranted to be free from defects in workmanship and materials under normal use and service. 2. This warranty is in effect for: a. 3 Years from date of purchase by the end user for standard products offered in our catalog. b. 2 Years from date of manufacture for non-standard or OEM products c. 1 Year from date of manufacture for encapsulated products. 3.
An ISO9001 and AS9100 Registered Company Battery Chargers • Inverters • Power Supplies • Voltage Converters 8128 River Way, Delta B.C. V4G 1K5 Canada T. 604.946.9981 F. 604.946.9983 TF. 800.668.3884 (US/CANADA) www.analyticsystems.