INSTALLATION & OPERATION MANUAL VTC180 DC/DC Converter An ISO9001 and AS9100 Registered Company Battery Chargers • Inverters • Power Supplies • Voltage Converters 8128 River Way, Delta B.C. V4G 1K5 Canada T. 604.946.9981 F. 604.946.9983 TF. 800.668.3884 (US/CANADA) www.analyticsystems.
Copyright (2005-2014) Analytic Systems Ware (1993) Ltd.
IMPORTANT & SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS — This manual contains important safety and operating instructions for the converter. 1. GENERAL 1. WARNING — Unless the label specifically states that the converter may be used for battery charging, it must not be used for that purpose. 2. CAUTION — To reduce risk of injury, charge only lead acid or sealed gel cell type rechargeable batteries. Other types of batteries may burst causing personal injury and damage. (Applies to battery chargers only!) 3.
Introduction The VTC180 Series Voltage Converter is a variable duty cycle switching power supply with a precision linear regulator output. It can be configured to run from a 32, 48 or 72 VDC power systems to provide output voltages as shown below. The VTC180 Series Voltage Converter features reverse input protection, current limiting, output over-voltage protection, ultra quiet low EMI operation and a wide operating temperature range.
Designed and manufactured by: ANALYTIC SYSTEMS WARE (1993) LTD. 8128 River Way Delta, BC V4G 1K5 p. 604.946.9981 f. 604.946.9983 tf. 800.668.3884 US/Canada Canada www.analyticsystems.com analyticinfo@analyticsystems.com Revised September 2014 Installation MOUNTING Mount the unit in a DRY location. Allow at least 1 inch of clearance around the unit for adequate cooling. RED INPUT POWER OUT VOLTAGE CONVERTER INPUT ii - II VDC OUTPUT oo.o VDC XX AMP CONT.
Operation As soon as power is supplied to the input leads the outputs become energized. Troubleshooting If the current demanded by the devices connected to the unit exceed the maximum output current rating, the output voltage will drop to maintain the current at the maximum level. If the fuse blows whenever it is turned on, check that the power leads are connected to the battery with the correct polarity; if they are then the unit is damaged and must be returned for repair.
Limited Warranty 1. The equipment manufactured by Analytic Systems Ware (1993) Ltd. (the “Warrantor”) is warranted to be free from defects in workmanship and materials under normal use and service. 2. This warranty is in effect for: a. 3 Years from date of purchase by the end user for standard products offered in our catalog. b. 2 Years from date of manufacture for non-standard or OEM products c. 1 Year from date of manufacture for encapsulated products. 3.