INSTALLATION & OPERATION MANUAL VTC315 SERIES Voltage Converter An ISO9001 and AS9100 Registered Company Battery Chargers • Inverters • Power Supplies • Voltage Converters 8128 River Way, Delta B.C. V4G 1K5 Canada T. 604.946.9981 F. 604.946.9983 TF. 800.668.3884 (US/CANADA) www.analyticsystems.
Copyright (2005-2013) Analytic Systems Ware (1993) Ltd.
IMPORTANT & SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS — This manual contains important safety and operating instructions for the voltage converter. ALL VOLTAGE CONVERTERS 1. WARNING – Unless the label specifically states that the voltage converter may be used for battery charging, it must NOT be used for that purpose. 2. Do not expose voltage converter to rain or snow. 3.
Specifications Input Voltages Nominal (ip) 24 48 72 Actual (Vdc) 20 – 35 40 - 60 65 - 90 Input Amps (max) 22.1 11.1 6.8 Input Fuse MDA-25 MDA-15 MDA-10 Output Voltages Nominal (op) 12 24 48 Output Volts (DC) 13.6 ± 0.05 27.2 ± 0.05 54.4 ± 0.05 Output Adjust ±1.0 V Output Amps 20 cont. / 22.5 peak 10 cont. / 12.5 peak 5 cont. / 6 peak Output Crowbar 16.0 ± 0.5 V 32.0 ± 1.0 V 63.9 ± 2.
Installation OUTPUT TERMINAL TO REMOTE INPUT FUSE INPUT POWER ON/OFF Allow at least 1 inch of clearance all around the case for cooling. The best mounting configuration is to mount the unit on a vertical surface oriented as shown. Use #10 screws of the appropriate type for the mounting surface to securely mount the unit. There is 1500 volts (500V for 24V Input) of isolation between the input and output, and the input and case.
Operation To turn the unit on, simply move the power switch to the ON position. The alarm buzzer will sound and the Low Output LED will come on briefly, and then the green OUTPUT ON LED will illuminate. The unit’s output voltage is preset at the factory. You may check this voltage at the output terminals of the unit with a good digital voltmeter. If you wish to adjust the output voltage, use a very small flat blade screwdriver to rotate the potentiometer.
Dry Contact Relay To use the dry contact output fail relay you must connect a 9-pin D connector to the unit. You must use pins one and six as indicated in the remote control diagram on page 7. The relay is factory preset to fail in the closed position when the converter is OFF or the low output LED and buzzer come on. If you wish to have the relay fail in the open position when the low output LED and buzzer come on, you must take the cover off the unit and move the jumper to the other position on J13.
Special Services & Options Conformal Coating INCLUDED ON ALL UNITS UNLESS REQUESTED NOT TO as of April 1, 2014 Option “c” Ruggedization Package (EXTRA Conformal Coating and RTV Compound) Option “v” Marine / Industrial Pkg (EXTRA Conformal dipping and RTV Compound) Option “MS” Military Pkg (incl.
Limited Warranty 1. The equipment manufactured by Analytic Systems Ware (1993) Ltd. (the “Warrantor”) is warranted to be free from defects in workmanship and materials under normal use and service. 2. This warranty is in effect for: a. 3 Years from date of purchase by the end user for standard products offered in our catalog. b. 2 Years from date of manufacture for non-standard or OEM products c. 1 Year from date of manufacture for encapsulated products. 3.