A8520E24A91 – User’s Manual Page 19 of 36
Release Date 01/23/15
Anaren Integrated Radio (AIR)
3. Electrical Characteristics
3.1. Absolute Maximum Ratings
Under no circumstances must the absolute maximum ratings given in Table 4 be violated.
Stress exceeding one or more of the limiting values may cause permanent damage to the
device.
Table 4 Absolute Maximum Ratings
Parameter
Min
Max
Unit
Condition/Note
Supply Voltage (Vdd)
-0.3
3.6
V
Voltage on any digital pin
-0.3
Vdd+0.3,
max 3.6
V
RF input power
0
dBm
Storage Temperature
-50
150
˚C
Solder reflow temperature
260
˚C
According to IPC/JEDEC J-STD-020D
ESD
<500
V
According to JEDEC STD 22, method
A114, Human body model
ESD
400
V
According to JEDEC STD 22, C101C,
Charged Device Model (CDM)
Caution!
ESD sensitive device. Precaution should be
used when handling the device in order to
prevent permanent damage.
Caution!
This assembly contains moisture sensitive
devices and requires proper handling per
IPC/JEDEC J-STD-033