12
1
Exceeding these written values may damage the drive and will cause unexpected operation of the digital outputs. These
outputs are ‘open collector’ type and have no current limiting or diagnostic features. It is up to the customer to ensure
compatibility of the external circuitry with this limit.
12.4 Electrical Specifications
Catalogue Number
D2003-2S1-A
D2009-2S1-A
Attribute
Symbol
Qualification
12.4.11 Power supply section
Drive Input voltage
U
LN-(1Ø)
U
LL-(3Ø)
100~240VAC
100~240VAC
Voltage fluctuation
U
δ
+/- 10%
Input frequency
ƒ
LN
50/60Hz
Maximum input voltage to Protective Earth
U
L1,L2,L3 -PE
265V AC
Auxiliary input current
I
LN
500 mA
Soft Start Relay
Internal
12.4.12 Digital servo drive
DC voltage
U
DC
1.404xU
LN-(1Ø-3 Ø)
Max. output voltage
U
aN1
0.90x U
LN-(1Ø-3 Ø)
Continuous output current
I
aN
3 A rms
9 A rms
One-minute overload capability
I
aM
110%
Peak repetitive overload current
I
p
6 A rms
16 A rms
Max. Peak repetitive overload duration
t
p
1 sec
Min. Peak repetitive overload interval
t
s
10 sec
Current loop update rate
t
i
62.5 sec, 125 sec
*
Drive efficiency
η
D
>90%
Max. Output frequency (at nominal
U
LN
)
ƒ
max
500 Hz