Instructions / Assembly
System Start-Up
1. Turn on both, cold-water supply and under-sink feed-water valve,
but close the tank ball valve. If there is any leak, turn off supply
and correct before proceeding.
2. Check system for leaks; tighten when necessary.
3. Open RO faucet and keep it in ON position.
4. After 5 minutes, the water will start to drip out of the RO faucet.
Let it drip for about 10 minutes and then close the faucet. Turn on
tank ball valve. It will take several hours (2-3) for the storage tank
to fill, depending on local water pressure.
5. After the tank is full (you will hear water stop), flush the system
by placing RO faucet in open position until water is completely
discharged.
6. Upon complete discharge of storage tank, close the RO faucet and
let the refilling process begin. This process could take 2-3 hours to
complete.
7. After the second tank is filled, you may enjoy the pure water.
8. Check for leaks daily during first week of use and periodically
thereafter.
9. You may notice that water is milky colored during the first week.
This is an indication of air bubbles in water; it is normal and safe.
Preventive Maintenance
This recommendation is intended for maximum efficiency of RO water
production by your system.
1. Filter maintenance
a. It is OK to store filters for several years.
b. To keep the unopened filter sealed, place it into an airtight
container, preventing it from absorbing air. This prolongs shelf life of
carbon filter and avoids any possible odor from the air.
2. Membrane maintenance
a. The dry-packed membrane usually has a two-year shelf life. To
prolong the shelf life, keep unopened dry membrane in refrigerator.
DO NOT DRINK WATER FROM THE FIRST TANK
PRODUCED BY YOUR NEWLY PURCHASED SYSTEM