Instructions / Assembly

Troubleshooting
Note: Turn off the system before servicing or inspecting
CAUSE
SOLUTIONS
Air in system
Air in the system is a normal
occurrence with initial startup of
the RO system. This milky look will
disappear during normal use within
1 to 2 weeks.
Air gap faucet
Will disappear after system shut
down.
Location of drain saddle
Relocate the drain to above water
trap.
Restriction in drain line
Blockage sometimes caused by
debris from garbage disposal or
dishwasher
System just starting up
Normally it takes 2
3 hours to fill
tank. Low water pressure and/or
temperature can reduce production
rate.
Air pressure in the storage
tank is low
Add pressure to storage tank. The
pressure should be 8
10 psi when
the tank is empty.
Low water pressure
Add a booster pump.
Crimps in tubing
Make sure tubing is straight.
Clogged pre
-filters
Replace pre
-filters.
Fouled membrane
Replace membrane.
Post carbon is depleted
Replace post carbon.
Fouled Membrane
Replace membrane.
Sanitizer not flushed out
Drain storage tank and refill it
overnight.
Clogged flow restrictor
Replace flow restrictor.
Fittings are not tightened
Tighten fittings as necessary.
Twisted O
-ring
Replace the O
-ring.
Misalignment of hole in the
drain saddle valve
Realign drain saddle valve.