Installation Guide

1) If the range hood or halogen light does not
operate after installation:
2) The range hood vibrates when the blower is on:
3) The blower or fan seems weak:
4) The lights work but the fan is not spinning at
all, is stuck or is rattling:
5) The hood is not venting out properly:
TROUBLE SHOOTING:
Check if the range hood has been plugged in,
make sure that all power has been turned back
ON,fused not blown and all electrical wiring
are properly connected.
The range hood might not have been secured
properly on to the ceiling or wall.
Check that the duct sized used is at least 6” or
3-1/4 x 10”. Range hood WILL NOT function
efficiently with insufficient duct size. For
example: 7” duct over 6” hole and loosely
secured.
Check if duct is clogged or if damper unit
(half-circular flange) is not installed correctly
or opening properly. A tight mesh on a side
wall cap unit might also cause restriction to the
air flow.
The fan might be jammed or scraping the
bottom due to shipping damage. Please
contact us immediately.
Make sure the distance between the stove top
and the bottom of the hood is within 24” and
30” in distance; with minimum 30” for gas
stove top.
Reduce the number of elbows and length of
duct work. Check if all joints are properly
connected, sealed, and taped.