Installation Guide
1.
Check if the range hood has been plugged in, make
sure that all power has been turned back ON, fused
2. The range hood vibrates when the blower is on: Ŗ The range hood might not have been secured prop-
erly on to the ceiling or wall.
3. The blower or fan seems weak: Ŗ Check that the duct sized used is at least 7” or 3-1/4
x 10”. Range hood WILL NOT function efſciently
with insufſcient duct size. For example: 8” duct
over 7” hole and loosely secured.
Ŗ Check if duct is clogged or if damper unit (half-cir-
cular ƀapper) is not installed correctly or opening
properly. A tight mesh on a side wall cap unit might
also cause restriction to the air ƀow.
4. The lights work but the blower is not spinning at all, Ŗ
is stuck or is rattling.
The blower might be jammed or scraping the bot-
tom due to shipping damage. Please contact us im-
mediately.
5. The hood is not venting out properly: Ŗ Make sure the distance between the stove top and
the bottom of the hood is within 24” and 30” in
distance; with minimum 30” for gas stove top.
Ŗ Reduce the number of elbows and length of duct
work. Check if all joints are properly connected,
sealed, and taped.
Ŗ Make sure the power is on high speed for heavy
cooking.
If the range hood or LED light does not operate Ŗ
after installation:
Troubleshooting :
15
not blown and all electrical wiring are properly con-
nected.
Swap out light assembly to working ones to deter-
mine whether it is caused by defective bulbs. See
Replacing the Light Bulb on Page 23.