Installation
IMPORTANT:
• Observeallgoverningcodesandordinances.
• It is the customer’s responsibility to contact a qualified electrical installer.
• Ifcodespermitandaseparategroundwireisused,itisrecommendedthataqualifiedelectrician
determinethatthegroundpathisadequate.A120-Volt,60Hz,AC-only,fusedelectricalsupplyis
required on a separate 15-amp circuit, fused on both sides of the line.
• DONOTgroundtoagaspipe.
• Checkwithaqualifiedelectricianifyouarenotsurethattherangehoodisproperlygrounded.
• DONOThaveafuseintheneutralorgroundcircuit.
IMPORTANT: Save this Installation Guide for electrical inspector’s use.
GROUNDING INSTRUCTIONS:
• Thisappliancemustbegrounded.Intheeventofanelectricalshort-circuit,groundingreducestheriskof
electric shock by providing an escape wire for the electric current.
• Thisapplianceisequippedwithacordhavingagroundingwirewithagroundingplug.Theplugmustbe
plugged into an outlet that is properly installed and grounded.
WARNING: Improper grounding can result in a risk of electric shock.
• Consultaqualifiedelectricianifthegroundinginstructionsarenotcompletelyunderstood,orifdoubt
exists as to whether the appliance is properly grounded. DO NOT use an extension cord. If the power
supply cord is too short, have a qualified electrician install an outlet near the appliance.
STEP 12
Connect to AC
• Connect AC plug into a grounded AC outlet having 120V,
60Hz.Placetheoutletatamaximumdistanceof33-1/2”
(851 mm) from where the cord exits on the hood.
• SEE IMPORTANT INSTRUCTIONS BELOW
3-Pronged Plug
Ground Plug
3-Prong Receptacle