Installation Guide
INSTALLATION:
SAFETY WARNING:
Risk of electrical shock. This range hood must be properly grounded. Make sure this is
done by a qualified electrician in
accordance with
all
applicable
national
and
local
electrical codes.
Before
connecting wires, switch power off at service panel and lock
service panel to prevent power from being switched on accidentally.
Step 6: Install Adapter/Damper
• Using 4 no. 8 x 3/8' screws from parts bag, assemble the adapter/damper on the top of the power
pack. To ensure proper opening of the dampers, remove shipping tape if present. Seal all joints with
metal foil duct tape to eliminate air leaks.
•
Using 2 no. 8 x 3/8" screws from parts bag, assemble the adapter on the top of the power pack. Seal
all joints with metal foil duct tape to eliminate air leaks.
• Install 8" damper inside the VERTICAL ductwork that will be attached to power pack. Do not install
in a horizontal ductwork or it will not open and close properly. Remove shipping tape if present. To
optimize airflow and quiet sound, position the damper at least 17 " above the top of the power pack;
or as far as the duct will allow (see Fig#10). Secure the damper to the duct with 3 no. 8 metal screws
(not provided). Ensure damper opens and closes freely. Seal all joints with metal foil duct tape to
eliminate aire leaks.
11
Step 5: Remove Knock-Out Opening
•
From inside the power pack, remove the wiring cover by removing 2 retaining screws and set aside. Punch
out the electrical knockout hole on top of the power pack. Install the wire clamp (included in parts bag).
Fig#5
Fig#6
Fig#7
Fig#8
Fig#9
Fig#10