Installation Guide
1-888-686-0778
1)
If the range hood or LED light does not
operate after installation:
2) The range hood vibrates when the blower is on:
3) The blower or fan seems weak:
4) The lights work but the fan is not spinning at
all, is stuck or is rattling:
5) The hood is not venting out properly:
TROUBLE SHOOTING:
•
Check if the range hood has been plugged in,
make sure that all power has been turned back
ON, fused not blown and all electrical wiring
are properly connected.
• The range hood might not have been secured
properly on to the ceiling or wall.
•
Check that the duct sized used is at least 6”.
Range hood WILL NOT function efficiently
with insufficient duct size. For example: 7”
duct over 6” hole and loosely secured.
• Check if duct is clogged or if damper unit
(half-circular flange) is not installed correctly
or opening properly. A tight mesh on a side
wall cap unit might also cause restriction to the
air flow.
•
The fan might be jammed or scraping the
bottom due to shipping damage. Please
contact us immediately at 1-888-686-0778.
• Make sure the distance between the stove top
and the bottom of the hood is within 24” and
30” in distance; with minimum 30” for gas
stove top.
• Reduce the number of elbows and length of
duct work. Check if all joints are properly
connected, sealed, and taped.
15