Wall and Under Cabinet Range Hood User Manual and Installation Instructions IMPORTANT SAFETY INSTRUCTIONS Carefully read the important information regarding installation, safety and maintenance. Keep these instructions for future reference.
Before You Begin INSTALLERS - Start Here Safety Instructions are on pages 4 and 5 and Installation Instructions are on pages 10 to 17. Please perform these steps: 1. Read the safety instructions. 2. Read all instructions in the Installation section of this manual BEFORE installing the range hood. 3. Remove all packing materials. 4. When finished, make sure to leave these instructions with the consumer. 5. Installation is to be done by a qualified technician only.
Table of Contents Before You Begin................................................................................................................................ 2 Table of Contents............................................................................................................................... 3 Important Safety Information............................................................................................................. 4 Included Parts..............................................
Important Safety Information READ ALL INSTRUCTIONS BEFORE USE Read and follow all instructions before using the range hood to prevent the risk of fire, electric shock, personal injury, or damage when using the range hood or appliances with the range hood. This guide does not cover all possible conditions that may occur. Always contact your service technician or manufacturer about problems that you do not understand.
Important Safety Information WARNING: TO REDUCE RISK OF A RANGE TOP GREASE FIRE: To reduce the risk of injury to persons in the event of a gas leaks: a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. • Extinguish any open flame. • DO NOT turn on the lights or any type of appliance. • Open all doors and windows to disperse the gas.
Included Parts Wall Hoods Upper Chimney Bracket Lower Chimney Lower Chimney Bracket Main Housing Hood Mounting Bracket 2 + 1 Screws Upper Chimney Damper flap 2 Filters Included Parts Under Cabinet Hoods Main Housing 2 Filters Damper 4 + 1 Screws Hardware Note: For safety reasons, range hood mounting screws and anchors will not be included due to the variation of cabinetry constructions and wall material.
Dimensions for Cabinet Hoods Dimensions for 24 inch wide units 54.9 cm (21.6 in.) 8 cm (3.1 in.) 14.8 cm (5.8 in.) 25.5 cm (10 in.) 6.1 cm (2.4 in.) 15.3 cm (6 in.) 54.9 cm (21.6 in.
Mounting Brackets for Wall Hoods Type I Upper Chimney Bracket 0.8 cm (0.3 in.) 20.4 cm (8 in.) 18.01 cm (7.1 in.) 16.51 cm (6.5 in.) 0.6 cm (0.2 in.) 0.5 cm (0.2 in.) 2.5 cm (1 in.) 2 cm (0.75 in.) Lower Chimney Bracket 19.35 cm (7.6 in.) 18.77 cm (7.4 in.) 16.5 cm (6.5 in.) 15 cm (5.9 in.) 0.5 cm (0.2 in.) 2.5 cm (1 in.) 2 cm (0.75 in.) Mounting Bracket Hook 175 mm (6.8 in.) 40 mm (1.5 in.) 6 mm (0.2 in.) 8 mm (0.3 in.) 19 mm (0.75 in.) 28 mm (1.1 in.) 199 mm (7.8 in.) 160 mm (6.3 in.) 20 mm (0.
Mounting Brackets for Wall Hoods Type II Upper Chimney Bracket 31.8 cm (12.5 in.) 31.8 cm (12.5 in.) 27.9 cm (11 in.) 27.9 in.) 20.4cm cm (11 (8 in.) 0.8 cm (0.3 in.) 2.5 cm (1 in.) 2.5 cm (1 in.) 18.01 cm (7.1 in.) 16.51 cm (6.5 in.) 0.6 cm (0.2 in.) 0.5 cm (0.2 in.) 2.5 cm (1 in.) 2 cm (0.75 in.) Lower Chimney Bracket 19.35 cm (7.6 in.) 30 cm (11.8 in.) 30 cm (11.8 in.) 18.77cm cm(10.3 (7.4 in.) 26.2 in.) 26.2 cm (10.3 in.) 16.5 cm (6.5 in.) 15 cm (5.9 in.) 0.5 cm (0.2 in.) 2.5 cm (1 in.
Installation STEP 1 Read the Safety Instructions • It is very important to read the safety instructions on pages 4 and 5. IMPORTANT: It is the installer’s responsibility to comply with installation clearances. STEP 2 Unpack Range Hood and Prepare Tools • Carefully unpack the range hood and parts. Make sure all parts are included as shown on page 6. • DO NOT remove the protective film covering the appliance until the installation is fully completed.
Installation STEP 5 Venting Installation Guidelines • The following steps are for exterior ventilation. For the most efficient and quiet operation: IMPORTANT: • Vent system must terminate to the outside (roof or side wall). • DO NOT terminate the vent system in an attic or other enclosed area. • DO NOT use 4 in. (10.2 cm) laundry-type wall caps. • Use metal/aluminum vent only. A rigid metal/aluminum vent is recommended. • DO NOT use a plastic vent. • Always keep the duct clean to ensure proper airflow.
Installation IMPORTANT: • A minimum of 6 in. (15.3 cm) round or 3-1/4 x 10 in. (8.3 cm x 25.4 cm) rectangular duct must be used to maintain maximum airflow efficiency. • Always use rigid type metal/aluminum ducts if available to maximize airflow when connecting to provided duct. • Please use Duct Run Calculation below to compute total available duct run when using elbows, transitions and caps. • ALWAYS, when possible, reduce the number or transitions and turns.
Installation STEP 6 Preparations NOTE: To avoid damage to your hood, prevent debris from entering the vent opening. • Determine and mark the center line on the ceiling or wall where the range hood will be installed. • Make sure there is proper clearance within the ceiling or wall for exhaust vent. • Due to the weight and size of this unit, please make sure that the support system or framework being used is stable and secure in the ceiling or wall.
Installation • Optional step: For extra support, drill 2 additional holes aligned to hood’s pre-drilled holes, to mount the hood onto the wall. (See Figure #2) STEP 9A (wall hoods only) Venting Fig. #2 • Fix the damper flap on the top vent of hood. • If ventilation system is equipped with an external air duct with a different diameter, apply a reduction fitting. However, for maximum performance and safety, a 6 in. round ducting is recommended. (See Figure #3) Fig.
Installation IMPORTANT: • Observe all governing codes and ordinances. • It is the customer’s responsibility to contact a qualified electrical installer. • If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate. A 120-Volt, 60 Hz, AC-only, fused electrical supply is required on a separate 15-amp circuit, fused on both sides of the line. • DO NOT ground to a gas pipe.
Installation STEP 7B (cabinet hoods only) Attaching Vent/Damper • Remove the two filters to allow access to the inside of the unit. • Depending on the exterior venting option chosen (See page 12), pop out the steel panel on either the top or rear of the range hood. (See Figure #8) • Using the supplied screws, attach the rectangular vent/ damper to the rear of the range hood. (See Figure #9) Fig. #8 Fig.
Installation IMPORTANT: • Observe all governing codes and ordinances. • It is the customer’s responsibility to contact a qualified electrical installer. • If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate. A 120-Volt, 60 Hz, AC-only, fused electrical supply is required on a separate 15-amp circuit, fused on both sides of the line. • DO NOT ground to a gas pipe.
Operation Off Low speed Medium speed Power Settings u v w x u Medium speed button: Starts the fan at medium speed. High speed button: Starts the fan in high speed. Low speed High speed Medium speed Light / Timer Lights Off button: Turns off the fan, does not turn off light. u Low speed button: Starts the fan in low speed mode. Medium speed button: Starts the fan at medium speed. Decrease Press button once to turn light on and off. Light works independently from fan.
Maintenance Replacing the Light Pucks IMPORTANT: ALWAYS SWITCH OFF THE ELECTRICITY SUPPLY AT THE MAIN PANEL BEFORE CARRYING OUT ANY OPERATION ON THE APPLIANCE. u Make sure the range hood is unplugged or turn OFF breaker. w Replace LED lights. Plug in new puck and push back into light panel. v Remove filters, push the spring, pull out the LED puck and unplug it. x Turn ON breaker and range hood to test for operation.
Maintenance Cleaning Filters IMPORTANT: Drain oil from spacers, filters, oil tunnels, oil containers before oil and residue overflow! • Remove all spacers, filters, grease tray, and oil containers and discard oil and residue. • Wash with warm soapy water. NOTE: Filters, spacers and oil tunnel are top rack dishwasher safe. • Dry thoroughly before replacing and follow directions for installation in reverse. • Filters should be cleaned after every 30 hours of use.
Use and Care Information Operations • Read and understand all instructions and warnings in this manual before operating the appliance. Save these instructions for future reference. • Always leave safety grills and filters in place. Without these components, operating fans could catch on to hair, fingers and loose clothing. • NEVER dispose cigarette ashes, ignitable substances, or any foreign objects into fans. • NEVER leave cooking unattended.
Please register your product warranty by visiting the Ancona Home website. Canada & USA Phone: 1-888-686-0778 Fax: 800-350-8563 Email: service@anconahome.com Website: www.anconahome.com Ancona is in association with Mr Appliance for all after sales service calls. Please contact their service provider or visit their website: Phone: 888-998-2011 Website: www.mrappliance.com MAANTM01-02 © 2019 Copyright of Ancona Home. All rights reserved.