Use and Care Manual

Isolate the cooktop from the gas supply piping system by closing its individual manual
shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or
less than 1/2 psig (3.5 kPa or 14" water column).
Electrical Connection
Before making the connection, make sure that:
1) The safety circuit-breaker and the electrical system are able to with stand the load of the
appliance.
2) The power supply system has a ground connection in good working order in accordance with the
regulations in force.
3) The electrical socket is easily accessible with the appliance installed. In all cases, the power
supply lead must be positioned so that it does not reach a temperature 50
o
C above the room
temperature at any point.
4) If installed above a built-in oven, the cooktop cable must not touch the oven below (see Figure 15).
Assembling the Burners
Figure 15
25