Installation
WARNINGS:
• PleasemakesuretoreadALLsafetyprecautionsonpages4to10.
• ExplosionHazard.
• UseanewCSAInternationalapprovedgassupplyline.
• Installashut-offvalve.
• Securelytightenallgasconnections.
• IfconnectedtoLP,haveaqualifiedpersonmakesuregaspressuredoesnotexceed14”(36cm)watercolumn.
Examples of a qualified person include: licensed heating personnel, authorized gas company personnel, and
authorized service personnel.
• Failuretodosocanresultindeath,explosion,orfire.
DANGER:
• ThisapplianceisoutfittedfromthefactorytobeusedwithONLYonetypeofgas.Thisrangeistobeconnectedwith
agassupplyline.Thegasconnectionisamale1/2”BSPandislocatedroughly2-1/4”fromthein from the right
hand side of the appliance and 22” from the ground. The hose must be free of kinks or other deformations that would
inhibit its ability to supply gas to the unit or cause a gas leak. Keep gas line s free from contact with any moving parts
such as a drawer to prevent damage or obstruction.
DANGER:
The gas supply line must be equipped with an approved manual shut-off valve. The shut-off valve must be in an
easily accessible location in the same room as the appliance. Do not block access to the shut-off valve. Be sure
you know how and where to shut off the gas supply to the range.
STEP 4
Gas Connection
u
INSTALL THE PRESSURE REGULATOR: This appliance is set for natural gas and is designed to operate at 5”
water column pressure. The gas supply is required to provide a minimum of 4” to a maximum of 14” water column
pressure to the appliance regulator. The pressure regulator must be connected in series with the manifold of the
appliance and must remain in series with the supply line regardless the type of gas being used.
For proper operation, the gas pressure regulator supplied with this range must be used. The inlet pressure to the
regulator should be as shown in the chart below.
If the appliance is converted for liquid petroleum (LP) gas, the LP gas supply is required to provide a minimum of
10” to a maximum of 14” water column to the cooktop regulator.