Full Product Manual

— 18 —
Installation
STEP 5 (Optional)
(Must be done before Step 6 if converting to Propane)
Liquefied Pet oleum (Propane)
Gas Conversion
ThisappliancecanbeusedwithNaturalGasorLP/Propane
Gas. It is shipped from the factory for use with Natural Gas. A
kit for converting to LP gas is supplied with your appliance.
Thekitismarked“FORLP/PROPANEGASCONVERSION”.
u
When the range is converted for Liquid Petroleum
(LP) Gas, the LP gas supply is required to provide a
minimum of 10” to a maximum of 14” water column
to the range regulator.
Following LP Gas
Conversion, complete
Steps2to14:“Adjusting
the Regulator Pressure”;
“ChangingBurner
Nozzles”;“Adjusting
Burner Flames”; and
“TestingFlameStability”
.
Adjusting the Regulator Pressure
v
Shut off the gas supply to the appliance by closing
the manual shut-off valve. (See Figure 11)
w
Unscrew the regulator
cap with a wrench.
(See Figure 12)
x
Remove retainer pin by pulling it out. (See Figure 13)
y
Reverse the retainer pin and snap it back into the
regulator cap. (See Figure 14)
U
Screw the regulator cap back into the regulator and
re-attachittothenippleandareunionasshown.
DO NOT over-tighten. (See Figures 15 and 16)
WARNINGS:
• PleasemakesuretoreadALLsafetyprecautionson
pages 4 to 10.
• Failuretomaketheappropriateconversionafter
Step 4 can result in serious personal injury and
property damage.
The conversion must be performed by a qualified
service technician in accordance with the kit instruc-
tions and all local codes and requirements. Failure
to follow instructions could result in serious injury or
property damage. The qualified agency performing this
work assumes responsibility for the conversion.
Joint Joint
Off
On
Manual
Shut off
Valve
Pressure
Regulator
Flare
Union
Flare
Union
Gas Flow
Access
Cap
Figure 11
Figure 12
Figure 15
Figure 16
Figure 13
Figure 14