User Manual

Provide an Adequate Gas and Electrical
Supply
Installation must comply with local codes. In the absence of local codes, the gas cooktop must
comply with the National Fuel Gas Code ANSI Z223.1latest edition in the United States, or in
Canada CAN/CGA B149.1, and CAN/CGA B149.2, and the National Electrical Code ANSI/NFPA No.
70latest edition in United States, or in Canada CSA Standard C22.1, Canadian Electrical Code,
Part 1, and local code requirements.
Gas supply should be located near the
opening for this cooktop and be a minimum of
1” from the back wall (see Figure 7). This
cooktop is set for natural gas and is designed
to operate at 5” water column pressure. The
regulator is required to provide a minimum of
6” water column to a maximum of 14” water
column to the cooktop regulator.
The electric spark ignition feature for this model requires a 120V electrical power supply and should
be located 12” below the countertop and within reach of the cooktop’s four-foot power cord.
Tools and Materials Needed
MATERIALS YOU WILL NEED:
Joint Sealant Pipe Fittings Shut-Off Valve
Figure 7
19