Specification Sheet
anden.com
Form No. 6568 • 305017 11.20
©2020 Research Products Corporation
ANDEN RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE.
P.O. Box 1467
Madison, WI 53701-1467
800.972.3710 F: 608.257.4357
Drain Requirements
Placement
Model A77 Control (Included) External Control w/ Dry Contacts
The Model A710V3 can be controlled with the Model A77 Control (included) or any external control that can provide a
dry contact closure. When the Model A77 is used, the User Interface on the dehumidier MUST BE set to “Remote”.
For all other external controls, the User Interface MUST BE set to “External”. Refer to the quick start guide or installation
manual for instructions on accessing the installer set-up menu.
The Model A710V3 has a negative pressure cabinet that
requires a vented drain and drain trap (both included). The
drain lines should have a constant downward slope all the
way to the oor drain or condensate pump. The end of
the drain line should not be submerged in water to avoid
microbial growth.
Included:
• ¾ PVC drain trap
• ¾ PVC Vent T
• PVC Connectors