5.7 Annealed, or 5.7 Tempered Glass - w/ No Grilles and Grilles Less Than 1"
No Grilles AND-N-25-00385-00001 0.30 1.70 0.33 0.58 22 0.01 54
N NC - - A - - -
Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-25-00391-00001 0.30 1.70 0.30 0.52 20 0.01 54
N NC SC - A - - -
Full Divided Lite (FDL) AND-N-25-00397-00001 0.32 1.82 0.30 0.52 17 0.01 54
- NC SC - A - - -
Finelight™ (grilles-between-the-glass)
n/a n/a n/a n/a n/a n/a n/a n/a
- - - - - - - -
No Grilles AND-N-25-00386-00001 0.31 1.76 0.20 0.31 13 0.01 54
- NC SC S A - - -
Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-25-00392-00001 0.31 1.76 0.18 0.28 12 0.01 54
- NC SC S - - - -
Full Divided Lite (FDL) AND-N-25-00398-00001 0.32 1.82 0.18 0.28 10 0.01 54
- NC SC S - - - -
Finelight™ (grilles-between-the-glass)
n/a n/a n/a n/a n/a
n/a n
/a n/a - - - - - - - -
N
o Grilles AND-N-25-00387-00001 0.30 1.70 0.23 0.52 16 0.01 54
N NC SC S A - - -
Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-25-00393-00001 0.30 1.70 0.21 0.46 15 0.01 54
N NC SC S A - - -
Full Divided Lite (FDL) AND-N-25-00399-00001 0.31 1.76 0.21 0.46 13 0.01 54
- NC SC S A - - -
Finelight™ (grilles-between-the-glass)
n/a n/a n/a n/a n/a n/a n/a n/a - - - - - - - -
N
o Grilles AND-N-25-00384-00001 0.33 1.87 0.50 0.63 28 0.01 53
- - - - A B - -
Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-25-00390-00001 0.33 1.87 0.46 0.57 26 0.01 53
- - - - A B - -
Full Divided Lite (FDL) AND-N-25-00396-00001 0.34 1.93 0.46 0.57 24 0.01 53
- - - - A - - -
Finelight™ (grilles-between-the-glass)
n/a n/a n/a
n/a n
/a n/a n/a n/a - - - - - - - -
S
imulated Divided Lite (SDL) or Installed Interior Removable AND-N-25-00391-00002 0.30 1.70 0.27 0.46 18 0.01 54
N NC SC S A - - -
Finelight™ (grilles-between-the-glass) AND-N-25-00403-00001 0.32 1.82 0.30 0.52 17 0.01 54
- NC SC - A - - -
Full Divided Lite (FDL) AND-N-25-00501-00001 0.32 1.82 0.27 0.46 16 0.01 54
- NC SC S A - - -
Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-25-00392-00002 0.31 1.76 0.17 0.25 11 0.01 54
- NC SC S - - - -
Finelight™ (grilles-between-the-glass) AND-N-25-00404-00001 0.32 1.82 0.18 0.28 10 0.01 54
- NC SC S - - - -
Full Divided Lite (FDL) AND-N-25-00502-00001 0.32 1.82 0.17 0.25 10 0.01 54
- NC SC S - - - -
Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-25-00393-00002 0.30 1.70 0.19 0.41 14 0.01 54
N NC SC S A - - -
Finelight™ (grilles-between-the-glass) AND-N-25-00405-00001
0.31 1.
76 0.21 0.46 13 0.01 54
- NC SC S A -
- -
F
ull Divided Lite (FDL) AND-N-25-00503-00001 0.31 1.76 0.19 0.41 12 0.01 54
- NC SC S - - - -
Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-25-00390-00002 0.33 1.87 0.41 0.50 23 0.01 53
- - - - A - - -
Finelight™ (grilles-between-the-glass) AND-N-25-00402-00001 0.34 1.93 0.46 0.57 24 0.01 53
- - - - A - - -
Full Divided Lite (FDL) AND-N-25-00500-00001 0.33 1.87 0.41 0.50 23 0.01 53
- - - - A - - -
U.S.
ENERGY STAR
2010
U-Factor¹
Metric
SHGC²
VT³
Condensation
Resistantance
Andersen®
Product Line
& Product
Type
Air Infiltration
5.7 Annealed, or 5.7 Tempered Glass - w/ Grilles 1" or Greater
Grille Type
NFRC Certified
Products
Directory Number
Andersen
Glass
Type
Canada
ENERGY STAR
2010
Canada ER
Low-E4®
Sun
Low-E4®
Sun
U-Factor¹
400 Series
Springline™
Window
Low-E4®
SmartSun™
Low-E4®
PassiveSun™
Low-E4®
Low
-E4®
SmartSun™
Low-E4®
PassiveSun™
Low-E4®