Energy Guide
Northern
N. Central
S. Central
Southern
Zone A
Zone B
Zone C
Zone D
VT³
Canada ER
NFRC Certified Products
Directory Number
U-Factor¹
SHGC²
Grille Type
Andersen®
Product Line &
Product Type
Andersen
Glass Type
U.S.
ENERGY STAR
2010
Canada
ENERGY STAR
2010
Air Infiltration
U-Factor¹
Metric
Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-60-00668-00003 0.32 1.82 0.26 0.43 15 0.01
-NCSCSA---
Full Divided Lite (FDL) AND-N-60-00680-00001 0.33 1.87 0.26 0.43 14 0.01
--SCS ----
Finelight™ (grilles-between-the-glass)
n/a n/a n/a n/a n/a n/a n/a ---- ----
Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-60-00669-00003 0.33 1.87 0.17 0.23 9 0.01
--SCS ----
Full Divided Lite (FDL) AND-N-60-00681-00001 0.33 1.87 0.17 0.23 9 0.01
--SCS ----
Finelight™ (grilles-between-the-glass)
n/a n/a n/a n/a n/a n/a n/a ---- ----
Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-60-00670-00003 0.32 1.82 0.18 0.39 10 0.01
-NCSCS ----
Full Divided Lite (FDL) AND-N-60-00682-00001 0.33 1.87 0.18 0.39 9 0.01
--SCS ----
Finelight™ (grilles-between-the-glass)
n/a n/a n/a n/a n/a n/a n/a ---- ----
Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-60-00667-00003 0.33 1.87 0.40 0.48 22 0.01
---- A---
Full Divided Lite (FDL) AND-N-60-00679-00001 0.34 1.93 0.40 0.48 21 0.01
---- A---
Finelight™ (grilles-between-the-glass)
n/a n/a n/a n/a n/a n/a n/a ---- ----
No Grilles AND-N-60-00578-00004 0.31 1.76 0.33 0.56 20 0.01 -NC-- A---
Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-60-00578-00005 0.31 1.76 0.30 0.50 19 0.01 -NCSC- A---
Full Divided Lite (FDL) AND-N-60-00584-00002 0.33 1.87 0.30 0.50 16 0.01 --SC- ----
Finelight™ (grilles-between-the-glass) AND-N-60-00596-00002 0.31 1.76 0.30 0.50 19 0.01 -NCSC- A---
No Grilles AND-N-60-00579-00004 0.32 1.82 0.21 0.31 12 0.01 -NCSCS ----
Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-60-00579-00005 0.32 1.82 0.19 0.28 11 0.01 -NCSCS ----
Full Divided Lite (FDL) AND-N-60-00585-00002 0.33 1.87 0.19 0.28 10 0.01 --SCS ----
Finelight™ (grilles-between-the-glass) AND-N-60-00597-00002 0.32 1.82 0.19 0.28 11 0.01 -NCSCS ----
No Grilles AND-N-60-00580-00004 0.31 1.76 0.22 0.51 14 0.01 -NCSCSA---
Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-60-00580-00005 0.31 1.76 0.20 0.45 13 0.01 -NCSCSA---
Full Divided Lite (FDL) AND-N-60-00586-00002 0.33 1.87 0.20 0.45 11 0.01 --SCS ----
Finelight™ (grilles-between-the-glass) AND-N-60-00598-00002 0.31 1.76 0.20 0.45 13 0.01 -NCSCSA---
No Grilles AND-N-60-00577-00004 0.32 1.82 0.51 0.62 30 0.01 N --- ABC-
Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-60-00577-00005 0.32 1.82 0.46 0.55 27 0.01 N --- AB--
Full Divided Lite (FDL) AND-N-60-00583-00002 0.34 1.93 0.46 0.55 24 0.01 ---- A---
Finelight™ (grilles-between-the-glass) AND-N-60-00595-00002 0.32 1.82 0.46 0.55 27 0.01 N --- AB--
Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-60-00578-00006 0.31 1.76 0.27 0.45 17 0.01
-NCSCSA---
Full Divided Lite (FDL) AND-N-60-00590-00002 0.33 1.87 0.27 0.45 15 0.01
--SCS ----
Finelight™ (grilles-between-the-glass) AND-N-60-00602-00002 0.31 1.76 0.30 0.50 19 0.01
-NCSC- A---
Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-60-00579-00006 0.32 1.82 0.17 0.25 10 0.01
-NCSCS ----
Full Divided Lite (FDL) AND-N-60-00591-00002 0.33 1.87 0.17 0.25 9 0.01
--SCS ----
Finelight™ (grilles-between-the-glass) AND-N-60-00603-00002 0.32 1.82 0.19 0.28 11 0.01
-NCSCS ----
Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-60-00580-00006 0.31 1.76 0.18 0.40 12 0.01
-NCSCS ----
Full Divided Lite (FDL) AND-N-60-00592-00002 0.32 1.82 0.18 0.40 10 0.01
-NCSCS ----
Finelight™ (grilles-between-the-glass) AND-N-60-00604-00002 0.31 1.76 0.20 0.45 13 0.01
-NCSCSA---
Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-60-00577-00006 0.32 1.82 0.41 0.49 24 0.01
N --- A---
Full Divided Lite (FDL) AND-N-60-00589-00002 0.33 1.87 0.41 0.49 23 0.01
---- A---
Finelight™ (grilles-between-the-glass) AND-N-60-00601-00002 0.32 1.82 0.46 0.55 27 0.01
N --- AB--
No Grilles AND-N-60-00608-00004 0.31 1.76 0.33 0.56 20 0.01 -NC-- A---
Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-60-00608-00005 0.31 1.76 0.30 0.50 19 0.01 -NCSC- A---
Full Divided Lite (FDL) AND-N-60-00614-00002 0.33 1.87 0.30 0.50 16 0.01 --SC- ----
Finelight™ (grilles-between-the-glass) AND-N-60-00626-00002 0.31 1.76 0.30 0.50 19 0.01 -NCSC- A---
No Grilles AND-N-60-00609-00004 0.31 1.76 0.20 0.31 13 0.01 -NCSCSA---
Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-60-00609-00005 0.31 1.76 0.18 0.27 12 0.01 -NCSCS ----
Full Divided Lite (FDL) AND-N-60-00615-00002 0.33 1.87 0.18 0.27 9 0.01 --SCS ----
Finelight™ (grilles-between-the-glass) AND-N-60-00627-00002 0.31 1.76 0.18 0.27 12 0.01 -NCSCS ----
Low-E
Low-E
Sun
3.1 Pattern Glass - w/ No Grilles and Grilles Less than 1"
3.1 Pattern Glass - w/ Grilles 1" or Greater
3.9 Pattern Glass - w/ No Grilles and Grilles Less than 1"
Low-E
SmartSun™
5.7 Annealed, 5.7 or Tempered Glass - w/ Grilles 1" or Greater
Low-E Low-E
Low-E
PassiveSun™
Low-E
Sun
Low-E
SmartSun™
Low-E
PassiveSun™
Low-E
Sun
Low-E
Low-E
Sun
Low-E
SmartSun™
Low-E
PassiveSun™
200 Series DH
Fixed, AT, CT &
Transom (w/
Capillary
Breather Tubes)
Page 14 of 49
Data is current as of February 11, 2013
and is subject to change. See page 1 for more information.