Datasheet

www.andersonpower.com
- 40 -
All Data Subject To Change Without Notice
PP180 Silver Plated Busbar Contacts
Use 2 busbar contacts per housing to provide a quick disconnect input or
output busbar connection. Busbar contacts are for mating with wire contacts
only. Part number 180BBS includes lock nuts. Locknuts must be ordered
separately for 180BBS-BK.
Mating
Thread Force ------ Loose Piece Part Numbers ------
Minimum Quantity ................ 1,000 120 10 .....
Busbar 1/4-20 High 180BBS-BK 180BBS -
Lock Nut 1/4-20 N/A H1216P7 110G56 110G55
| PP180 SPECIFICATIONS |
Electrical
Current Rating Amperes¹ UL 1977 CSA
Singlepole (wire-wire) (3/0 AWG) 350 230
2x2 Block (wire-wire) (3/0 AWG) 350
Singlepole (wire-busbar) (1/0 AWG) 180
Voltage Rating AC/DC
UL 1977 600
Dielectric Withstanding Voltage
Volts AC 2,200
Avg. Mated Contact Resistance Milliohms¹
6” of 1/0 AWG wire 0.100
UL Hot Plug Current Rating Amperes
250 cycles at 120V DC 75A
Mechanical
Wire Size Range AWG mm²
Wire Contacts with Bushings 10 to 3/0 5.3 to 85
Max. Wire Insulation Diameter in. mm
0.900 22.860
Operating Temperature² °F °C
-4° to 221° -20° to 105°
Mating Cycles No Load by Plating Silver (Ag)
Wire and Busbar Contacts 10,000
Avg. Mating / Unmating Force Lbf. N
Wire & Busbar Contacts 10 44
Min. Contact / Spring Retention Force Lbf. N
120 534
Materials
Housing
Plastic Resin Polycarbonate
Contact Retention Spring Stainless Steel
Housing Flammability Rating
UL94 V-0
Contact
Base Copper Alloy
Plating Silver
Contact Termination Methods
Crimp³
Hand Solder
Wrench / Socket*
*Busbar Contacts Only
¹ Based on: 105°C rated or better cable of the largest size, Properly calibrated APP
®
recommended tooling, and
a 25°C ambient temperature. UL rating not to exceed the maximum operating temperature. CSA rating below a
30°C temperature rise.
² Limited by the thermal properties of the connector plastic housing.
³ Use APP
®
recommended tooling only. Alternate tools may adversely affect the performance of our connectors
along with UL and CSA recognition.
SECTION 2
Powerpole
®
PP180
Protection
Touch Safety with Wire Contacts
IEC 60529 IP10
See Busbar contact drawing on
website for further detail.
[ 4.6 ]
0.18
[ N/A ]
1/4-20
[ 2.7 ]
0.50
[ 25.4 ]
1.0
[ 109.7 ]
4.3