PP180 ACCESSORIES
Panel
Mounting Clamp
2 Pole 3 Pole
A
B
Mounting Clamp
Mounting clamps can be used for fastening a block of
Powerpole
®
180 series housings to a panel. Connector
blocks must be a complete square for the clamps to work
properly. Fastening hardware not included.
Description Part Numbers
Minimum Quantity 20 sets of 2
2 Pole 1465G1
3 Pole 1465G2
Retaining Pins
Retaining pins are used to keep stacked Powerpole
®
180 series housings from separating.
Retaining pins are inserted in the circular opening between two housings stacked side by side.
Dimension “B” is +/- .015 in or .38 mm.
Dimensions
- A - - B -
Description Part Numbers inches mm
Minimum Quantity 1,000 100
1 Block High 111812P6 110G18 0.196 / 0.207 4.98 / 5.26 1.000 25.400
2 Block High 111812P8 110G20 0.196 / 0.207 4.98 / 5.26 1.500 38.100
Reducing Bushings
Use with contact part number 1382-BK to allow a smaller wire to be used with the connector. Electrical
capability is derated with smaller wire.
Dimensions
Contact Barrel Size Wire Size - ID -
AWG mm² AWG mm² Part Numbers inches mm
Minimum Quantity 1,500 1,000 500 100
1/0 53.5 1 42.4 - - 5687-BK 5687 0.39 9.91
1/0 53.5 2 33.6 5690-BK - - 5690 0.34 8.64
1/0 53.5 4 21.2 - 5693-BK - 5693 0.27 6.86
1/0 53.5 6 13.3 - 5663-BK - 5663 0.22 5.59
1/0 53.5 10 to 8 5.3 to 8.4 5648-BK - - 5648 0.19 4.83
NOTE: Combinaon of a bushing and contact is not UL approved.
ID
Wire Entrance
[ 25.4 ]
1.0
For environmentally sealed connector shells to hold Powerpole
®
15 to 180 connectors, see SPEC Pak
®
product series on our
website www.andersonpower.com