Visual alarms:
Two control LEDs are
provided on the TFAxxx
front side.
The green LED describes
the power supply status,
while the red LED
describes the major Remote
Unit failures.
Dry contact alarms:
TFAxxx is provided with
two dry contacts inputs,
which can be connected
(through .062” MOLEX
plugs) to any external
device (ie. the TFBW
booster). In such a way, the
alarm information about
this external device can be
signalled through the red
LED of TFAxxx LED panel
stated above.
Led colour
Meaning
Red
Low optical power at DL input
and/or RF amplifier failure
Green Power supply status
Power supply:
TFAxxx can be powered by universal mains (85/265 Vac) and by negative supply (-72/-36 Vdc).
Power supply adapter is included in the remote unit and can be external or internal according to the
different models and part numbers:
Case A: internal for all models with only exception of TFAN20 that has external adapter
Case B: always external adapter for all models
Case A Remote Unit (except TFAN20)
These Remote Units are provided with internal power supply both for the 220VAC option and for the
-48VDC option. As shown in the figure below different power supply connectors are provided for the
two versions:
Dry contacts are open under
non-alarm condition
TFAxxx LED
dr
y
contacts
-48VDC version
(4 poles connector)
220VAC version
(IEC connector)