User's Manual

U
SER
´
S MANUAL FOR BAND SELECTIVE REPEATERS
MR
X
03P
User'sManual.doc Id.-No.:154999 Page 37 22-Jan-01
The following table and the example show how to use the rotary-switches*:
Switch
Description
S1 Channel code x100
S2 Channel code x10
S3 Channel code x1
S4 Channel code x100
S5 Channel code x10
S6 Channel code x1
S7 Attenuation in 2 dB steps upto 30 dB for UL-path
S8 Attenuation in 2 dB steps upto 30 dB for DL-path
S9 Code switch for motherboard
* Factory settings are: S1-S8 in position 0, DIP-switch 1 of mode switch [1] in position Off” (Automatic
mode). Switch S9 can be set to position 0 to 3 depending on the location of the motherboard in the
repeater.
table 5-3 Rotary switches of the motherboard
Example:
A gain of 74 dB is required in the UL- and DL-path, module 1 is set to channel 96 and
module 2 to channel 113. The repeater has a gain of max. 82 dB.
1. Calculate the difference between the max. repeater gain and the required gain.
Max. repeater gain: 82 dB
Required gain for UL and DL: 74 dB
-------------
Required attenuation for UL and DL: 8 dB
2. Turn switch S7 as well as S8 to position 4 to set an attenuation of 8 dB for UL- and
DL-path.
3. Set channel 96 for module 1:
Turn switch S1 to position 0: 0
Turn switch S2 to position 9: 90
Turn switch S3 to position 6: 6
--------
Channel: 96
4. Set channel 113 for module 2:
Turn switch S4 to position 1: 100
Turn switch S5 to position 1: 10
Turn switch S6 to position 3: 3
--------
Channel: 113