User's Manual

120
ION-B User Manual
TPRF
TPRF31 Installation
The TPRN kit provides:
1 TPRF31 sub-rack
1 power supply cable
1 standard RS232 cable (male-female)
3 Alarm-output connectors
3 Auxiliary input connectors
1 Cd-rom, including ION-B manuals and tools
The TPRF31 Fast MiniRack is provided with some
reversible brackets and suitable both for rack-
mounting and for wall-mounting.
Straight from the factory, the TPRF31 has brackets for
rack-mounting which cannot be removed for wall
mounting (see fi gure 4.2.9).
Warning (recommended when designing or installing)
Providing correct heat dissipation
For correct use of the TPRF31 sub-rack, it is important to verify if:
the TPRF31 has been mounted in a vertical position (please refer to the “TPRF31
Installation” section), the power supplying ports (located on the TPRF31, front side, Figure
4.2.7) have been turned upwards
the TPRF31 has been mounted on a rack (please refer to the “TPRF31 Installation”
section), a minimum distance of 1 HE has to be kept between nearby TPRN sub-racks to
ensure proper heat dissipation. The rack containing the TPRN sub-racks has to be large
enough to guarantee this correct distance between Master Units.
Setting the dip-switches in a multi sub-rack system
If you are installing a multi-sub-rack system, remember to assign each sub-rack an exclusive
binary address, by properly setting dip-switches 1, 2, 3, 4, 5 on the TPRF31 backplane (see
Fig. 4.2.6 and Table 4.2.3). Dip-switch 5 has to be set on each TPRN sub-rack in order to fi x
the baud rate for the RS485 and RS232 ports. Connecting the TPRNs through the RS485 port is
necessary when supervising the whole multi sub-rack system through the remote supervision
unit (to be set at the same baud rate).
Figure 4.2.9:
Some of the installation accessories
provided with the TPRF31
- (a) power supply cable;
- (b) 3-pole alarm-output connector
- (c) 2-pole auxiliary input connector,
- (d) 1 Cd rom, including ION-B manuals
and tools
(a)
(b)
(c)
(d)