ION-B User Manual
TFAM
Case B
Remote Units are provided with cooling fi ns which allow the optimization of heat
dissipation. In order for them to function properly, the mounting environment should allow
for the necessary air changeover
It is strongly recommended not to mount the external power supply on a horizontal
surface because this position does not allow heat dissipation. External power supplies
must be mounted on vertical surfaces.
In order to assure proper heat dissipation, external power supplies must be mounted in a
vertical position with the power socket downwards (see Fig. 3.3.6 a,b).
Once you have chosen a location for the Remote Unit, please follow these instructions:
1. In order to install the M4 screw anchors (not included) which hold up the TFAx Remote
Unit, drill into the wall according to the proper layout shown in Fig. 3.3.9.
2. Fix the TFAx to the wall by fi rmly tightening the screws into the anchors.
3. In order to install the M4 screw anchors (not included) which hold up the power supply
external adapter, drill into the wall according to the proper layout of your power supply,
shown in fi g.3.4.10b
4. Fix the external power supply adapter to the wall by fi rmly tightening the screw into the
anchors.
5. Fix the splice holder inside the splice tray (not included) See Fig. 3.3.7 a,b.
6. Splice the optical fi bres and close the splice tray. While handling the fi bers, be careful not
to bend them.
7. Fix the splice tray beside the Remote Unit.
8. Connect the external adapter to the TFAx Remote Unit with the proper cable.
9. If the Remote Unit is -48 Vdc powered, use the -48 Vdc plug (included) in order to
connect the external adapter to the -48 Vdc supply (Fig. 3.3.6 b). If the Remote Unit
is 90/264 Vac-powered, fi x the 90/264 Vac plug (included) onto a power cord (not
included), and use this cable to connect the external adapter to the mains (Fig. 3.3.6 a).
10. Connect the antenna RF cables to the RF antenna ports. Connect the UL and DL optical
connectors.
11. Once the installation is fi nished, please follow the section “TFAx Case B Start-up” in order
to carry out a proper system start up.