Installing a CAP H
8 Unscrew the protective cover from the MAINS connector of the CAP H (see Figure 11 on page 47).
9 Insert the plug into the MAINS connector and tighten the clamping ring until it is hand tight. Do not
over-tighten the clamping ring.
10 Turn on the circuit breaker.
Connect the MAINS Power and Power on a DC CAP H
A CAP H requires M6 double-lug DC cable connectors with stud-holding spacing of 15.88 mm (5/8”), as shown
in Figure 12.
Figure 12. Required M6 Double-Lug DC Cable Connectors
The CAP H is powered on as soon as power is connected to it.
This section provides information for powering a DC CAP H. If you are installing an AC CAP H, go to
"Connect the MAINS Power and Power on an AC CAP H" on page 47.
The MAINS cable must be properly secured observing local regulations and electrical codes. Be sure to
allow enough slack in the cable at the CAP H to mount or dismount the cable into the DC MAINS connector
of the CAP H.
M6
15.88 mm
(5/8”)