Installing Subracks and PSUs in an Equipment Rack
Connect the CAT Cards
1 Followthestepsin"InstalltheCANandTENCards”onpage27toinstalltheCATCardsintotheWCS
SubrackSlotsL1-L4,asneededforthisCAT/TENinstallation.
2 UseCat6Acables(23AWGminimum)toconnectuptofourUAPstotheCATCardports1-4(oneper
port).WhetherornottheUAPiscascadeddetermineshowyouconnecttheCATCardtoaUAP,as
describedbelow.
Non-CascadedUAPS
Toconnectuptofourindividual,non-cascadedUAPstotheCATCardviaports1-4(oneperport).
UAP,UAP-N25,andUAP-X:connecttheCATCardporttotheUAPMainport.
CAPL:connecttheCATCardporttotheCAPLOpticalPort1.
AnEthernetdevicesuchasacameracanbeconnectedtotheAUXportofaUAPifAUTCardsare
installedintheTENorCAN.
UAP, UAP-N25
UAP-X
CAT Ports 1 - 4 to/from UAP Main port
CAT Ports 1 - 4 to/from CAP L Opcal Port 1
CAP L