User's Manual Part 1

ION
®
-E Series Hardware Installation Guide M0201AA
Page 32 © June 2017 CommScope, Inc.
Installing Subracks and PSUs in an Equipment Rack
Connect the AUT Cards
ThefollowingrulesapplytotheAUTCardports1-8.
TheoutsidenetworkthatsupportstheEthernetdeviceconnectedtotheUAPmustbeconnectedtothe
correspondingAUTCardandportofthesubrackcontainingtheCATcardtowhichtheUAPisconnected.
Ethernetbackhaulovertheopticallinkisnotsupported.
BecausethepathfromtheUAPAUXporttoanAUTportpathisapass-throughconnection,noextra
networksetupproceduresfortheEthernetdevicearerequired.
BecausetheUAP'sAUXportisconfiguredtosupportasecondUAPbydefault,therewillbeadelaybefore
theEthernetbackhaulpathattheAUTCardisreadytousewhenthedeviceisinitiallyconnected.When
anEthernetdeviceisconnectedtotheAUXportofaUAP,ION-Edetectsthedevice,re-flashestheUAPto
supportthedevice,andthenrebootstheUAP.TheUAPwillperformthere-flashandrebootprocess
whenevertheUAPorEthernetdeviceconnectedtotheAUXportischanged.TheUAP'sblueLEDwillblink
whilere-flashingwithoutinterruptingservice,buttheUAPwillexperienceashortserviceinterruptionof
approximately1.5minuteswhenitreboots.
TheAUTpathisindependentofthesignalsetassignedtoaUAP,however,themaximumtransport
bandwidthfortheUAPisreducedfrom320MHzto280MHzwhenanEthernetdeviceisconnectedtothe
UAP.
TheAUXportofacascaded(secondary)UAPcannotbeusedtoconnectanEthernetdevice.
TheAUTCardportsdonotsupplypower,however,theUAPdoessupplyRemotePoweroverCat6Ato
connectedEthernetdevices.
1Gbit/sand100Mbit/sEthernetdevicesaresupported.