User's Manual Part 3

M0201AA ION
®
-E Series Hardware Installation Guide
© June 2017 CommScope, Inc. Page 115
Installing CAP Ls
3 ConnecttheOpticalPort1connectorasappropriateforthisinstallation.
a ObtainSingleModeFiber(SMF)orMultiModeFiber(MMF)thatisofsufficientlengthtoreachfrom
theCAP
LtotheION-ECAN/TEN.[when would you use SM vs. MM?]
b RemovethedustcapfromtheOpticalPort1connectorandtheconnectorsontheSMorMMfiber.
c FollowthelocalcleaningtechniquetocleanOpticalPort1.
d CleantheconnectorsontheSMForMMFfollowingthefibersupplier’srecommendations.
e ConnectoneendoftheSMForMMFtotheOpticalPort1connectorandtheotherendto[to what
EXACTLY does the other end of the cable connect on the CAN/TEN or junction box
?]
UNRESOLVED: Opt 1 connects to the ION-E CAN/TEN to provide the main signal and power interface. We
need to identify what type of cable to use, and does the customer supply the cable or does
it ship with the CAP
L?
NOTE: The Optical Port 2 connector is plugged as it is not used in this configuration.
4 ConnecttheAuxiliaryconnectorasappropriateforthisinstallation.
a RaisetheleverontheEMI/IP67capontheAuxiliaryconnectorandremovethecap.
UNRESOLVED: The AUX port provides a cascade connection to additional local power or CAP L, or provides
a connection to external Ethernet devices such as WiFi and IP cameras. Spec stated that
cabling is via the appropriate CAT cable for installed unit protocol—what cable type(s) are
supported for each unit type to which it can connect?
UNRESOLVED: Verify that maximum attached cable length is 3 meters (9.8 feet).
UNRESOLVED: To what does the other end of the cable connect to on external Ethernet devices such as WiFi
and IP cameras?
5 ConnecttheVdcPowerconnectorasappropriateforthisinstallation.
a FindtheLocalPowerJumperCableAssemblythatwasshippedwiththemountingkit.
b Connectthefour-pinconnectortotheVdcPowerconnectorontheCAPL.
TheCAPLispoweredonassoonasyouconnecttheLocalPowerJumperCableAssemblytoapower
source;see
"PoweringaCAPL”onpage82.
UNRESOLVED: Spec stated that this model can connect to a local or external power supply, for each option,
to what does the power cable connect?