User's Manual

SPECIFICATIONS
ION-M17EHP/19P Remote Unit Cabinet Drawing
ION-M17EHP/19P - Product Specification
700 MHz Extension Unit ION-M7P EU
Frequency range, MHz
................Uplink ..............698 to 716
..........................................776 to 787
................Downlink ............728 to 757
RF output power per carrier *, dBm
Number of Carriers 1 2 4 8
LTE 43 40*** 37 34
Spurious emission......... . . . . . . . . . . . . . . . . . <-13 dBm / 1 MHz
DL output tolerance over frequency, dB ........±1
DL output tolerance over temperature, dB .......±0.5**
UL Input ICP3, dBm
................ICP3 optimized..........-11 min.
................Noise figure optimized......-18 min.
UL Noise figure, dB
................ICP3 optimized..........7
..................................10 max.
................Noise figure optimized .....4.5
..................................6 max.
* Applicable to single modulation mode only
** With active cooling
*** 2 dB reduction of Pout @ carrier bandwidth < 5 MHz
All figures are typical values unless otherwise stated.
UL-Amp
Duplexer
Unit
PowerAmplifier
NConnector
from /to
Mobile Station
Controller
RS485
DPX
700
MHz
2
ExtensionInterface
ION-M7P Extension Unit