7.2. SPECIFICATIONS
7.2.1. Electrical Specifications
Electrical
85 Vac to 264 Vac
Mains power
115 Vac or 230 Vac
max. temp., fully
loaded
550 watts
Power supply
Power consumption
room temp., idle 300 watts
Optical Link
Optical link connectors E2000/APC 8°
Optical return loss 45 dB
Fibre type Single mode E9/125 µm
Optical link budget 0 dB to 10 dB
7.2.2. Mechanical Specifications
Height, width, depth * 831 x 156 x 147 mm (32.7 x 6.1 x 5.8 in)
Weight, 20 kg (44 Ib)
* Spacing required 40 mm (1.58 in) around unit
All data is subject to change without notice.
7.2.3. Environmental and Safety Specifications
Note: For detailed information, please refer to the Environmental and
Safety Specifications leaflet of the supplier, related to ETS 300 019
(European Telecommunication Standard).
Operating temperature range -33° C to +50° C
RF part IP67
Ingress protection
Fan part IP55