User's Manual

Installation Instruction
The Remote Unit, Extension Unit or Master Unit has to be
mounted by proffessionel / special trained installer.
1.1. MECHANICAL INSTALLATION
1.1.1. General
Read the health and safety warnings in section 1.3.
1. Do not install the unit in a way or at a place where the specifications outlined in the Environmental
and Safety Specifications leaflet of the manufacturer are not met.
2. It is strongly recommended to install the unit vertically.
3. When mounting the Remote Unit, the connector flange (illustrated in chapter Fehler! Verweisquelle
konnte nicht gefunden werden. Fehler! Verweisquelle konnte nicht gefunden werden.) with the
cables must point to the ground. A maximum tilt angle of 25° to the horizontal position of the
connector flange must be kept in each mounting direction. For details, refer to chapter Fehler!
Verweisquelle konnte nicht gefunden werden. Fehler! Verweisquelle konnte nicht gefunden
werden.. If a different installation of the Remote Unit is required, please contact customer service for
further information.
4. It is recommended to use the mounting hardware delivered by the manufacturer only. If different
mounting hardware is used, the specifications for stationary use of the Remote Unit must not be
exceeded.
Note: Exceeding the specified load limits may cause the loss of warranty!
5. The unit is considerably heavy. Make sure that a suitable mounting surface is used. Ensure there is
adequate manpower to handle the weight of the system.