Installation Instruction

Installation Instruction
The Remote Unit, Extension Unit or Master Unit has to be
mounted by proffessionel / special trained installer.
1.1. MECHANICAL INSTALLATION
1.1.1. General
Read the health and safety warnings in chapter 1.3.
1. Warning: Do not install the unit in a way or at a place where the specifications outlined in the
Environmental and Safety Specifications leaflet of the supplier are not met.
2. Warning: It is recommended to use the mounting hardware delivered by the manufacturer
only. If different mounting hardware is used, the specifications for stationary use of the
Remote Unit must not be exceeded.
Note: Exceeding the specified load limits may cause the loss of warranty!
3. Warning: The unit is considerably heavy. Make sure that a suitable mounting surface is used.
Ensure there is adequate manpower to handle the weight of the system.
4. Caution: Due to power dissipation, the Remote Unit may reach a very high temperature.
Ensure sufficient airflow for ventilation.
5. Note: When connecting and mounting the cables (RF, optical, mains, ...) ensure that no water
can penetrate into the unit through these cables.
6. Note: Observe all additional rules or restrictions regarding mounting that apply to specific
Remote Unit types.
If any different or additional mounting material is used, ensure that the mounting remains as safe as the
mounting designed by the manufacturer. Ensure that the static and dynamic strengths are adequate for
the environmental conditions of the site. The mounting itself must not vibrate, swing or move in any
way that might cause damage to the Remote Unit.
Specified torques must be observed for certain mounting procedures according to the following table:
Type
Tallow-drop
screws
Hex
nuts
Spacing
bolts
PG
(plastic)
PG
(aluminium)
Thread
M 4
M 8
M 4
M 8
PG 13.5
PG 29
Specified torques
3.3 Nm
27 Nm
2.3 Nm
27 Nm
3.75 Nm
10 Nm

Summary of content (5 pages)