User's Manual

Wireless Innovations Group
2601 Telecom Parkway
Richardson, Texas 75082
400/800 MHz Fiber Optic & RF Fed Bi-Directional
Amplifier Operations / Maintenance Manual
DWG NO: AE04B-A1669
Rev: B
Date: 06/18/2008
Page:
63 of 63
7.4.6 BDA Connections
When tightening RF Type-N connectors located on the rear of the BDA, use a dedicated N-
Type torque wrench. If Type-N connectors are over-tightened, irreparable damage will occur.
Do not use adjustable pliers to loosen or tighten connectors.
When connecting or disconnecting the fiber optic cable connectors located on the front panel
of the fiber optic transceiver module, exercise caution not to touch the optical connector
center pin. In the event that the connector center pin needs cleaning, use only high quality
lens-grade tissue, moistened with isopropyl alcohol.