Unused CDU Ports
Any ports on the CDU that are not connected to an ERAU will cause the built-in-
test system in the InCell system to indicate a link error condition. This error
condition will be seen on the CDU front panel Link indicators and will also
appear as a Link error at the Alarm output.
In order to not set off the alarm, each unused CDU port must have a simplex fiber
optic jumper cable between the U/L and D/L fiber optic connectors. The jumper
must have SC/APC connectors on each end. Refer to the InCell Accessories
section of this manual for a jumper part number.
Mandatory UL Installation Notes
1. Do not operate unit above 50 decrees Celsius.
2. Installation of the equipment in a rack should be such that the amount of
airflow required for safe operation of the equipment is not compromised.
3. Mounting of the equipment in the rack should be such that a hazardous
condition is not achieved due to uneven mechanical load.