User Manual
Users Guide - Andrew InCell™ Fiber Optic Distributed Antenna System
1-8
InCell™ Specifications
Technical Performance
The InCell technical specifications are summarized in Table 1-1.
Table 1-1. InCell™ Performance Specification
Enhanced Remote Antenna Unit (ERAU) Specifications
Andrew Corporation
Wireless Service Standard InCell Part Number
SMR,iDEN,AMPS,CDMA,TDMA, GSM AE04A-D0602-001
800 MHz PCS
Specifications
Downlink Uplink Downlink Uplink
Frequency Range (MHz) 853-894 808-849 1850-1910 1930-1990
Maximum Input Power (dBm) 0 dBm -40 dBm limited 0 dBm -40 dBm limited
Return Loss (dB) > 16 dB >16 >16 > 16
Adjacent Passband Rejection (dB) > 50 > 50 > 50 > 27
Link Gain (dB) 25.0 ± 1.0 12.0 ± 1.0 30.0 ± 1.0 13.0 ± 1.0
Max Passband Variation (dB) 5.0 5.0 2.5 2.5
Output Power (Watts) 0.75 x 1.0 x
Output Third Order Intercept Point (dBm) 35 dBm x 37 dBm x
Spurious Response (dBm) < -13 - SMR x < -13 for PCS x
x < -36 for GSM x
Spur Free Dynamic Range (dB) x ≥ 75 x ≥ 75
Noise Figure (dB) ≤ 45 ≤ 16 ≤ 45 ≤ 14.5
Downlink wide band noise (dBm/Hz) < -121.5 dBm/Hz < -121.5 dBm/Hz
Optical Wavelength (nm) 1310 nm 1310 nm
POWER SPECIFICATIONS
Input Voltage Requirements 40 - 60 VDC
Typical Power Consumption 50 Watts
Power Supply Redundancy None
Backup Power Supply External