Operation and Maintenance Manual
385700-4006-006 INSTALLATION
Document use is restricted to that described on cover 2-10
The spectrum analyzer, if used, should be configured as follows:
Center Frequency 2416.64 MHz
Span 2 MHz
RBW 30 KHz
VBW 3 Hz
Ref. Level as required
Attach a ≥ 10 dB, 2 watt or greater, power attenuator to the spectrum analyzer RF input.
The direction control signal characteristics required will depend on the interface option
installed. The direction must be set to the NORMAL state.
Figure 2-7 PA Module Outline
2.5.2.2.2 PA Input Alarm Adjustment
Set the signal generator output to RF ON. Adjust the output level of the generator to 10 dB
less than the expected input level. If this level exceeds the range of the input detector, the
detector should be set to its minimum detectable level.
R1 = Input Threshold Set
R2 = Output Level Set
R3 = Output Threshold Set