User's Manual
Table Of Contents
- GENERAL MANUAL INFORMATION
 - PREPARATION FOR STORAGE OR SHIPMENT
 - DESCRIPTION OF EQUIPMENT
 - LOCATIONS AND DESCRIPTIONS OF MAJOR COMPONENTS
 - EQUIPMENT CHARACTERISTICS
 - INSTALLING THE RADIO EQUIPMENT
 - INTERCONNECTIONS
 - CABLE AND GROUND REQUIREMENTS
 - COMPONENT JACK LOCATIONS
 - INITIAL PREPARATION FOR USE
 - RADIO APPLICATION CODE UPGRADE
 - PN SPREADING CODE SELECTION
 - ANTENNA AND CABLE INSTALLATION
 - CONTROLS AND INDICATORS
 - STARTUP AND SHUTDOWN PRODECURES
 - OUTPUT POWER SETTINGS
 - ANTENNA PLACEMENT
 - FUNCTIONAL DESCRIPTION OF EQUIPMENT
 - PREVENTIVE MAINTENANCE, INSPECTION, AND CLEANING
 - TROUBLESHOOTING
 - CORRECTIVE MAINTENANCE
 - TEST PROCEDURES
 - MDR TESTS
 - BDR TESTS
 - RADIO DATA PORT TO USER SUPPLIED EQUIPMENT INTERFACE
 - PARTS LIST
 - BASE DATA RADIO MECHANICAL OUTLINE
 - DIAGNOSTIC MENU
 - MDR DIAGNOSTIC LCP MENU
 - LCP COMMANDS
 
385700-1006-006 INSTALLATION
Document use is restricted to that described on cover 1-7
Transmitter
Transmitter Center Frequency 2416.64 MHz
Output Power (+24 dBm linear) – adjustable
Transmitter Duty Cycle Up to 100% continuous operation
Modulation Gaussian Phase Shift Keying
Receiver
Receiver Center Frequency 2467.84 MHz
Receiver Input Impedance 50 ohms
Receiver Noise Figure
≤ 7 dB
Maximum Input 0 dBm
BER in AWGN
≤1 * 10E-05 for a –90 dBm input
Power Supply
Inputs 87 to 265 VAC, 47-63 Hz
Power Consumption <50 watts
Transient Protection Yes
Reverse Polarity protection NA
Environment
Operating Temperature -25°C to +70°C rack mounted
-40°C to +70°C pole mounted
Storage Temperature -50°C to +85°C
Operating Humidity 10 to 95%
Storage Humidity 10 to 95%
Shock NA
Vibration 0.4 g’s peak, 5-100 Hz
Physical
Size 15.0” (l) x 19” (w) x 5.22” (h) (indoor)
16.5” (l) x 13.0” (w) x 5.5” (h)
Weight <50 pounds
Enclosure Weatherproof (outdoor)
Standard 19” rack mount (indoor)
Regulatory
FCC Part 15 Compliant
Table 1-3 Base Station Radio Assembly Specifications