User guide
Bulletin II-102051-EN • Revision B  November-2007  11 
   !!
.  
Select the installation location. The PDU installs in a standard 19” rack (or 23” rack using a Rack 
Extender) in a climate controlled environment. It can be mounted in any orientation. Ensure optimum 
airflow around the instrument for cool operation and maximum life expectancy. 
Inspect the equipment. Ensure that all items are present, of the correct description, and without 
evident damage. 
Locate connection points for supply power, alarm interface, and Bias Tees. Determine the routing of 
cables. Verify that the supplied cables are sufficient to reach these points. If not, relocate the PDU or 
obtain cables of alternate length or style. 
.  0
The following tools and supplies may be required to complete the installation: 
•  Rack screws and screwdriver 
•  Needle-nose pliers (if repositioning the Alarm Range Selector) 
•  Ground cable with terminals, fasteners, wrench (10 mm), and other required tools 
•  Terminals for Power and Alarm Cables, wire stripper, and other required tools 
•  Fuse or circuit breaker for BTS power panel (1 – 5 A recommended) 
•  Torque wrench, 7 – 10 in-lbs (0.8 – 1.1 Nm), 8 mm or 5/16” 
•  Weather-sealing materials (for Bias Tee connections if outdoors) 
•  Cable ties and marking materials 
.  
   6,:4
Determine the applicable alarm current range based on the type of TMA used. See the table below 
for supported TMA current consumption ranges. 
'( )* & +* &
&' 23./4 5.6.74
8' .432. 5.622
Verify that the shunting block is correctly positioned in the Alarm Range Selector on the rear panel of 
the PDU (Figure 12). To reposition, pull out the shunting block using needle-nose pliers and reinsert 
it in the desired position. 
LO CURRENT MODE
HI CURRENT MODE
ALARM RANGE
SELECTOR
LO CURRENT
HI CURRENT
Figure 12: Alarm Range Selector 