11. Lift the mount assembly (3500 lb or 1588 kg) with the crane approximately
39.0 inches (1 meter) and remove the upper shipping brace. Extra care shall
be taken when attaching the steel lifting cable to prevent damage to the
ladder and platform (if installed).
12. Place several wood blocks under the lower end of mount while lifting the
mount to a vertical position.
13. Remove the lower shipping brace.
14. Place the lower azimuth pivot (item 3 on drawing 477697) over the
foundation anchor bolts and loosely install (Qty 6) 1.25 inch galvanized
washers (item 214) and (Qty 6) 1.25-7 UNC nuts (item 215).
15. Install (Qty 3) 3/4-10 X 3.0 screws into lower azimuth pivot base.
16. Place a surface level on the top surface of the lower azimuth pivot pin and
adjust (3) equally spaced 3/4-10 X 3.0 screws on the base plate until the pivot
is level. Tighten three of the six top nuts against the base plate to 240 ft-lb
(325 Nm).
17. Check the level to ensure the lower azimuth pivot pin is level.
18. Rotate the remaining (3) bottom nuts and (3) top nuts against the base plate.
Caution must be taken not to distort the leveled pin. Tighten all anchor nuts
to 240 to 275 ft-lb (325 to 372 Nm).
19. Install ΒΌ-20 X 1.0 eye bolt to upper azimuth pivot (item 2 drawing 477697).
Attach a string to the eye bolt and suspend a plum bob directly over the
lower azimuth pivot (item 3 drawing 477697).
20. Attach upper azimuth pivot (item 2) to legs (item 4) with 1.0-inch hardware
(items 201, 202 and 203).
21. Adjust the leg anchor bolts as required to install hardware. Tighten 1.0 inch
hardware to 600 ft-lb (813 Nm).
22. Remove the crane from the mount.
23. Adjust the anchor bolt nuts and leveling screws to the foundation as
required until the upper and lower pivot is plum (vertically aligned).
24. Attach wrench to the top and bottom 1-8 UNC foundation anchor
nuts and tighten to 240 to 275 ft-lb (325 to 372 Nm). Be sure to evenly
tighten the nuts so as not to distort the legs.
25. Attach azimuth mount (item 1) to the actuator (item 17) using ten 1.0-
8 X 3 galvanized bolts (item 218) and 1.0 galvanized flat washers (item
219).
26. Install centering arm (item 23) as shown on sheet 5 of drawing.