Operation Manual

Operating Instructions - Polar Wind
Click www.andrews-sykes.com or Call Us Free 0800 211 611
Dehumidifying and Cooling Operations
1. The operating range for dehumidifying is 10°C-30ºC (50°F-86°F) and the
operating range for cooling operating is 17°C-30°C (63°F-86°F).
2. If the cooling or dehumidifying operations have been switched off and need
switching on again in a short time, allow approximately three minutes for the
cooling or dehumidifying operations to resume.
3. Make sure the water pump drain hose is correctly connected to the unit.
Cooling Operation
1. Operating temperature range: 17ºC-30°C (63°F-86°F)
2. Press the
button several times until the indicator light comes on.
3. Press the
buttons to select your desired room temperature.
4. Press the
button to choose the fan speed.
Dehumidifying Operation
1. Operating temperature range: 13°C-32°C (55°F-90°F)
2. Press the
button several times until the indicator light comes on.
3. The fan will run at a fixed speed at this setting.
4. Keep windows and doors dosed for the best dehumidifying effect.
5. Do not put the duct to window.
Fan Operation
1. Press the button several times until the indicator light comes on.
2. Press the
button to choose the fan speed.
3. Do not put’the duct to window.
Timer Operation
1. Press the button when the air conditioner is off. Select the time you
need the unit to start to operate.
2. The Operation paned window will display “On”.
3. The starting time is adjustable from 00.00 to 24.
Setting the off timer:
1. Press the button when the air conditioner is on. Select the time you
need the unit to turn off. The Operation Panel Window will display “Off”.
2. The turning off time is adjustable from 0.00 to 24
Water Pump Drainage
Connect the water pump drain hose to the unit before operate. When the water
level of the internal water tank reaches a predetermined level, the water pump will
be activated and drain the condensed water outside through the connected drain
hose. (Under this condition, attach the rubber bung to the back hole to prevent
continuous drainage.) Fig. 4
Continuous Drainage
When you plan to leave this unit unused for a long time, remove the rubber bung
from the back hole and attach a section of the continuous drain hose connector.
All the water In the water tank will drain outside through the drain hose. (Under
this condition, the water pump is not activated). Fig. 5.
DIGITAL DISPLAY
FAN SPEED
Indication lights.
COOL/DRY/FAN indicator
Press this button will choose
high, middle or low speed of air
delivery.
TEMP SETTING buttons
This button sets the present time
and timer.
TIMER ON/OFF buttons
Program the timer on/off function
FAN SPEED button
Indication light.
WATER FULL
Indication light.
ON/OFF button
Pressing this button will turn the
machine on or off.
MODE button
Pressing this button will turn the
machine on or off.
POWER
Indication light.
INFRA RED RECEIVER
Fig.4
Filter
Drain
Water pump drain
Fig.5
Fig.1
Fig.3
Fig.2
Operating Controls