Model QPT Number Description
Digit 1, 2, 3 - Model
QPT Parallel flow fan powered terminal
Digit 4 - Heat options
S Standard
W Hot water coil
E Electric heat
Digit 5, 6, 7, 8, 9 - Cabinet size, Fan HP and Primary inlet size
1 17 06 1/6 hp 6” inlet
1 17 07 1/6 hp 7” inlet
1 17 08 1/6 hp 8” inlet
1 17 09 1/6 hp 9” inlet
1 25 06 1/4 hp 6” inlet
1 25 07 1/4 hp 7” inlet
1 25 08 1/4 hp 8” inlet
1 25 09 1/4 hp 9” inlet
2 17 09 1/6 hp 9” inlet
2 17 10 1/6 hp 10” inlet
2 17 12 1/6 hp 12” inlet
2 25 09 1/4 hp 9” inlet
2 25 10 1/4 hp 10” inlet
2 25 12 1/4 hp 12” inlet
Digit 10 - Casing Construction
B single wall 20ga. Steel (standard)
E double wall 22ga. Steel
(1/2” glass fiber insulation)
Digit 11 - Insulation and Treatment
0 None
1 1/2” matte-faced glass fiber insulation
(double wall only)
2 1” matte-faced glass fiber insulation (standard)
3 1/2” foil-faced glass fiber
(tape over all insulation edges)
4 1” foil-faced glass fiber
(tape covers insulation edges)
5 3/8” closed cell insulation (fiber free)
Digit 12 - Control Type
0 None
P Pneumatic
A Electronic Analog
F Supplied by others – factory mounted
Digits 13, 14, 15, 16 - Control Package
0000 None (field supplied by others)
XXXX Refer to available control packages
Digit 17 - Control location
(determined by facing inlet)
L left hand
Digits 18, 19, 20, 21 - Primary air minimum airflow
0000 None specified
XXXX Specify minimum airflow setting in CFM
Digits 22, 23, 24, 25 - Primary air maximum airflow
0000 None specified
XXXX Specify maximum primary airflow setting in CFM.
Digit 26 - Heating coil and connection location (determine
by facing inlet)
0 None
A One-row hot water coil - right hand
B One-row hot water coil - left hand
C Two-row hot water coil - right hand
D Two-row hot water coil - left hand
K Electric heat - connections same side as digit 17
Digit 27 - Fan Motor Voltage
1 115V/ 1 Ph./ 60 Hz.
2 277V/ 1 Ph./ 60 Hz.
Note: Standard motor is 3 speed multi-tap PSC
Digit 28 - Electric Coil Voltage and Steps
0 None
A 208V/ 1 Ph/ 60Hz. 1 step
B 208V/ 1 Ph/ 60Hz. 2 step
C 208V/ 1 Ph/ 60Hz. 3 step
D 240V/ 1 Ph/ 60Hz. 1 step
E 240V/ 1 Ph/ 60Hz. 2 step
F 240V/ 1 Ph/ 60Hz. 3 step
G 277V/ 1 Ph/ 60Hz. 1 step
H 277V/ 1 Ph/ 60Hz. 2 step
J 277V/ 1 Ph/ 60Hz. 3 step
K 208V/ 3 Ph/ 60Hz. 1 step
L 208V/ 3 Ph/ 60Hz. 2 step
M 208V/ 3 Ph/ 60Hz 3 step
N 480V/ 3 Ph/ 60Hz. 1 step
P 480V/ 3 Ph/ 60Hz. 2 step
R 480V/ 3 Ph/ 60Hz. 3 step
Note: 3 steps not available with night setback control packages
Digits 29, 30. 31 - Electric coil KW
000 None
XXX Refer to notes on pages 369 and 370 for
allowable range
Digit 32 and over - Options and Accessories
C1 Unit mounting brackets
C2 Manual damper locking quadrant (shipped loose)
C4 Hinged front panel control enclosure
C5 Discharge collar (“S” units only)
D3 Line voltage SPST disconnect switch (120V, 277V)
D5 Line voltage power-fusing
(fuse and block for 120V, 277V)
(terminal selector block standard)
D7 Three speed motor switch
(terminal selector block standard)
D8 Fan Relay, 24 VAC Coil, SPST / N.O.
(for DDC controls by others)
D9 24 VAC Electric Actuator
DA 24 VAC Transformer, 40 VA
E1 Non-fused interlocking disconnect switch
for Electric heat
E2 Electric heat Mercury de-energizing contactors
E3 Electric heat power fusing
(fuses and fuse blocks)
E4
Electric heat manual reset secondary thermal cutout
E6 AirFlow proving switch
F1 One inch throwaway filters
Standard Digits 1-3 4 5 6,7 8,9 10 11 12 13-16 17 18-21 22-25 26 27 28 29-31 32-33 34-35 36-+
Description Model Heat
Cabinet
HP Inlet Casing Insul Cntrl Cntrl LH Min Max Heat Fan Coil Elec Opt Opt Opt
Num
Size
Size Type Pkg CFM CFM Config VAC VAC KW
Example QPT W 1 17 06 B 1 A 5001 L 0100 1450 E 1 G 12.0 C1 C4 F1
2 50 09 1/2 hp 9” inlet
2 50 10 1/2 hp 10” inlet
2 50 12 1/2 hp 12” inlet
3 50 12 1/2 hp 12” inlet
3 50 14 1/2 hp 14” inlet
3 50 16 1/2 hp 16” inlet
3 75 12 3/4 hp 12” inlet
3 75 14 3/4 hp 14” inlet
3 75 16 3/4 hp 16” inlet
3 10 12 1 hp 12” inlet
3 10 14 1 hp 14” inlet
3 10 16 1 hp 16” inlet
Must be 4 wire
WYE configuration