User's Manual

33
33
LPR ADJUSTMENT
ANGEL™ 4
LPR ADJUSTMENT
The low-pressure regulator controls the pneumatic cycle of the ANGELand is located in
the left-hand chamber at the front of the ANGELbody. The pressure needs to be at
82 PSI (5.7) output at a pressure of 350 PSI at the second stage regulator.
LPR adjustment is achieved by the removal of shims. Each shim equals approximately
5 PSI/0.35 BAR. We recommend the use of the optional service tools and lubrication of parts
with Love Juice Extreme GREASE™ only (see GENERAL ASSEMBLY DIAGRAMS - pages 24-25).
· Ensure the ANGEL™ is de-gassed and switched OFF.
· Remove the left end cap using suitable metric 4.0 A/F Allen key.
· Insert the optional pressure gauge adaptor into the hole that the end cap was
removed from.
· Re-Gas the ANGEL™ and switch the ANGEL™ to LIVE.
· Fire 6 shots with
NO paintballs present to stabilize the LPR pressure.
Note the pressure reading. Should the reading be too high or low, proceed to the
next stage.
· Ensure the ANGEL™ is degassed and switched OFF.
· Remove the pressure gauge adaptor and insert an M 2.5mm screw or the piston
extracting tool (optional extra) into the brass piston and withdraw slowly.
· Remove the four piston springs .
· Add or subtract shims as necessary, note the number of shims may vary from
the diagram shown (maximum 20).
· Replace piston springs in correct order onto the piston.
· Re-insert the piston ensuring that it is located correctly.
· Insert the optional pressure gauge adaptor into the hole that the end cap was
removed from.
· Re-Gas the ANGEL™and switch the ANGEL™ to LIVE.
1 2 3 4 5 6 8 9 10 11 12 13 7
1 2 3 4 5 6 8 9 10 11 12 13 7
1 2 3 4 5 6 8 9 10 11 12 13 7
1 2 3 4 5 6 8 9 10 11 12 13 7
1 2 3 4 5 6 8 9 10 11 12 13 7
1 2 3 4 5 6 8 9 10 11 12 13 7
1 2 3 4 5 6 8 9 10 11 12 13 7
1 2 3 4 5 6 8 9 10 11 12 13 7
1 2 3 4 5 6 8 9 10 11 12 13 7
1 2 3 4 5 6 8 9 10 11 12 13 7
1 2 3 4 5 6 8 9 10 11 7
1 2 3 4 5 6 8 9 10 11 7
1 2 3 4 5 6 8 9 10 11 12 13 7
1 2 3 4 5 6 8 9 10 11 12 13 7
MAINTENANCE – LPR ADJUSTMENT
• Ensure a barrel blocking device is fitted to the ANGEL™
• Ensure the hopper is removed from the ANGEL™
• Ensure that there are no paintballs in the ANGEL™
Always remove the first stage regulator and relieve all residual gas pressure
from the ANGEL™ before disassembly.
• The ANGEL™ can hold a small residual charge of gas, typically 2 shots, with the
first stage regulator removed. Always discharge the marker in a safe direction to
relieve this residual gas pressure.
m
WARNING
ADHERE STRICTLY TO THESE
AND ALL OTHER SAFETY
INSTRUCTIONS AND GUIDELINES
• The ANGEL™ is live and capable of discharging.
m
WARNING
ADHERE STRICTLY TO THESE
AND ALL OTHER SAFETY
INSTRUCTIONS AND GUIDELINES
Always remove the first stage regulator and relieve all residual gas pressure
from the ANGEL™ before disassembly.
• The ANGEL™ can hold a small residual charge of gas, typically 2 shots, with the
first stage regulator removed. Always discharge the marker in a safe direction to
relieve this residual gas pressure.
m
WARNING
ADHERE STRICTLY TO THESE
AND ALL OTHER SAFETY
INSTRUCTIONS AND GUIDELINES
SPRING STACK
ORDER
1 2 3 4 5 6 8 9 10 11 12 13 7
1 2 3 4 5 6 8 9 10 11 12 13 7
1 2 3 4 5 6 8 9 10 11 12 13 7
1 2 3 4 5 6 8 9 10 11 12 13 7
1 2 3 4 5 6 8 9 10 11 12 13 7
1 2 3 4 5 6 8 9 10 11 12 13 7
1 2 3 4 5 6 8 9 10 11 12 13 7
1 2 3 4 5 6 8 9 10 11 12 13 7